Select[0/2] logs off, Program select log files 2016kb, File create logfile3 – ProgressiveRC 208B iCharger User Manual
Page 26: File empty? confirm(enter), File delete? confirm(enter)
-26-
iCharger Synchronous Balance Charger/Discharger 208B
Log Files Management
iCharger 208B has a 16Mbit flash storage, which can log offline charge and discharge data in 36 hours. The
users can transfer these data to logview for analyzing and plotting when it is necessary.
Batt type
stop
Select[0/2]
Logs OFF
Log files management. The value showed on the left side of the second line
is Free Capacity / Free Logging Time alternatively.
Manage the file. The first line shows‖Select[X/Y] nnnnn‖ (X: the sequence
number of the current selected file; Y: total number of the files; nnnnn: the
log number included in files). The second line shows the selected file name.
File Select: Press Inc or Dec to select.
Note: The number 0 means ―Logs OFF‖, if you select this item, it will turn off
Log File function.
File Create: Hold Inc for more than 3 seconds, the user can set up at
most 8 files.
File Transfer: Press Start/Enter for more than 3 seconds.
File Empty: Press Dec and Inc for more than 3 seconds.
File Delete: Press Batt type/Stop and Dec for more than 3 seconds.
PROGRAM SELECT
Log files 2016Kb
Start/Enter
>3 seconds
Dec Inc
Start/Enter
Batt type
stop
Free Capacity
&Free Time
File Create
LogFile3_
File Empty?
CONFIRM(ENTER)
File Transfer...
00050/01000
File Delete?
CONFIRM(ENTER)
User-defined the files name. (Name setting method: Press
Inc orDec to choose the letter, press Start/Enter to
confirm your selection and move to the next one, press
Batt type/Stop to delete the character.) After input, press
Start/Enter 2 times for confirmation, or press Start/Enter
for more than 3 seconds with a sound ―Di‖, iCharger takes
in the user setting to set up the files.
iCharger transfers the logging data to Logview software
via USB. The second line shows the two values are‖ have
transferred logging number/ the total logging number‖. In
the course of transferring, you can press Batt type/Stop to
stop it.
Note: The connecting steps of the receiving the data
operation into Logview is the same as iCharger charges
and discharges. See details in “Using logview for 208B”
(P30)
Press Start/Enter to empty the file, and press Batt
type/Stop to cancel it.
Press Start/Enter to delete the file, and press Batt
type/Stop to cancel it.
Inc
>3 seconds
Start/Enter
>3 seconds
Stop&Dec
>3 seconds
Dec&Inc