Kontron MOPSlcdLX User Manual
Page 11
KTD-S0006-B Page
8
Graphics
Interface
MOPSlcdLX Software Guide
3.3.2 DisplayID
TM
Restrictions
Depending on the graphic controller not all features can be used. The following table shows the most im-
portant restrictions.
Restrictions for MOPSlcdLX
Panels with dual or quad clock not supported (2 or 4 Pixel per Clock)
Variable power sequencing not supported
DisplayID
TM
is not a solution for every LCD. Many displays center the picture automatically using the DE-
signal. In general the picture is centered automatically in horizontal direction but some displays also cen-
ter the picture vertically using this signal. Only for displays that can be driven with a
fixed mode
timing a
displacement of the picture is possible. For these information please check the datasheet. With the
MOPSlcdLX board the parameters for the typical detailled timing out of the datasheet might not be correct
for centering the picture. In general the exact positioning of the picture has to be obtained experimental.
3.3.3
LCD Panel Selection
The choice of an LCD display is basically defined by two parameters.
Parameter
Value
Pixel per Clock (Channels)
1
Maximum Pixel Clock
135 MHz
Currently this leads to a maximum resolution of
1024 Pixel
With the AMD graphic driver it is not guaranteed that every resolution can be achieved. KONTRON does not
guarantee the correct function of the board for untypical resolution. In principal the use of DisplayID
TM
allows realizing every special display resolution. For this a valid DisplayID
TM
dataset must be written to the
onboard EEPROM. Additionally the BIOS Setup entry
Advanced Chipset Features/LCD Resolution
must be set to
Auto.