3 technical specification, 3 technical specification - 5, Om6040 subrack specifications - 5 – Kontron OM6040 Compact User Manual
Page 19: Introduction om6040

ID 1027-6427, Rev. 2.0
Introduction
OM6040
Page 1 - 5
1.3
Technical Specification
Table 1-1: OM6040 Subrack Specifications
FEATURES
SPECIFICATIONS
Shelf
MicroTCA™ cube form designed for Single Full-size AMC Modules
• Dimensions: 250mm x 157mm x 150mm (depth x width x height)
(with mounting panel)
• Slot geometry (from left side of the subrack):
slot 1: allocated for Single Full- or Mid-size AMC module
to
slot 4: allocated for Single Full- or Mid-size AMC module
slot 5: allocated for MicroTCA™ Single Full-size Carrier Hub - MCH
• Two fans: one located at bottom-front area of the shelf, and one in bottom of the
rear bay
• Rear bay area occupied by the power supply unit, CM, and small fan
Temperature Ranges:
• Operating:
0°C to +55°C
• Storage:
-40°C to +70°C
Humidity: 93% RH at 40°C, non-condensing
Weight: 2.8 kg shelf with fans and power supply unit
3.1 kg as above, plus MCH
Backplane and
Compatibility Module
MicroTCA™ compliant, single-tier backplane with:
• Four AMC module connectors
• One three tongue MCH connector
• DC/DC converters for 3.3 VDC management power
• PCIe clock routing to all AMC slots
• Two connectors for interfacing to the MCH Compatibility Module (CM)
Input power distribution and control functionality
Fan power distribution
Backplane FRU data EEPROM
Fabrics:
• Single-star Gigabit Ethernet Fabric (port 0 to each AMC slot; port 1 to AMC slots
1 and 3)
• Fat pipes are routed in a star configuration between AMC ports 4-7 to the MCH.
Depending on the MCH configuration (PCIe switch or SRIO switch) the fat pipes
may be used for 4x lanes of PCIe or 4x lanes of SRIO.
• Fat pipes routing: AMC ports 8-11: AMC slots 1-2 and 3-4
• SATA/SAS porting (AMC Ports 2 and 3):
• AMC#1 port 2 to AMC#2 port 2
• AMC#1 port 3 to AMC#3 port 2
• AMC#3 port 3 to AMC#4 port 2
IPMB-L and I²C interfacing supported for IPMI and local monitor and control