Detailed System Description
This system's configuration is based on the ISA architecture. Check the I/O and the Memory maps in this Chapter.
6.1 Incompatibilities to a Standard PC/AT
6.1.1 PC104 BUS / ISA BUS
An onboard LPC to ISA-bridge makes it possible to expand the functionality of the board with additional PC/104 cards.
Unfortunately, because of the transformation from LPC to ISA it is not possible to realize a 16bit access. This does not
mean that these cards cannot be used, but that the 16bit access is divided into two. Therefore the access to these
cards is a little bit slower.
Attention!
With the BEV version, this limitation is solved by using a PCI-ISA bridge. The disadvantage is that now 2
PCI devices are onboard and there are only 2 external PCI slots available.
6.1.2 Keyboard versus NUM-Lock
Without a connected keyboard, the NUM-Lock ON field in the BIOS setup
must not be
activated. Otherwise the time-
out noticeably slows down the reaction speed of the computer as soon as the keyboard is not connected. The PS2
peripherals (KB and MS) are not hot-plug compatible.
6.2 Related Application Notes
Application Notes are available at
http://support.kcc-ag.ch/
or on any KCC Application CD.
6.3 High Frequency Radiation (to meet EN55022)
Since the PC/104 CPU modules are very highly integrated embedded computers, peripheral lines are not protected
against radiation from the high frequency spectrum. To meet a typical EN55022 requirement, all peripherals that go
outside of the computer case must be externally filtered.
Typical signals that must be filtered:
Keyboard:
KBCLK, KBDATA and VCC
Mouse:
MSCLK, MSDATA and VCC
COM1/2/3/4: All serial signals must be filtered
LPT:
All parallel signals must be filtered
CRT:
Red, blue, green, hsynch and vsynch must be filtered
Typical signals that must not be filtered, since they are used internally:
IDE:
Connected to the hard disk
Floppy:
Connected to the floppy
LCD:
Connected to the internal LCD
6.3.1 For Peripheral Cables
Use a filtered version for all DSUB connectors. Select the filter specifications carefully. Place the filtered DSUB
connector directly on the front side and be sure that the shielding makes good contact with the case.
9pin
DSUB connector from AMPHENOL
FCC17E09P
820pF
25pin
DSUB connector from AMPHENOL
FCC17B25P
820pF