2 sensor thresholds, Sensor thresholds, Ipmi firmware am4020 – Kontron AM4020 IPMI Firmware User Manual
Page 32
IPMI Firmware
AM4020
Page 24
ID 1036-5671, Rev. 2.0
P R E L I M I N A R Y
4.2
Sensor Thresholds
The AM4020 CPU module is available for two different operating temperature ranges. For each
operating temperature range, a set of temperature thresholds for the sensors is defined. The
standard temperature range uses thresholds defined by Table 10, and the extended tempera-
ture range uses thresholds defined by Table 11. Table 12 provides voltage sensor thresholds.
Table 11: Thresholds - Standard Temperature Range
Sensor Number /
ID String
0Eh /
A1:Temp
CPU
0Fh /
A1:Temp
PCH
10h /
A1:Temp
MCH
16h /
A1:Temp
Air
Upper non-recoverable
115 °C
116 °C
110 °C
95 °C
Upper critical
105 °C
111 °C
100 °C
90 °C
Upper non-critical
95 °C
101 °C
90 °C
80 °C
Normal max.
90 °C
96 °C
85 °C
75 °C
Nominal
80 °C
86 °C
75 °C
65 °C
Normal min.
3 °C
3 °C
3 °C
0 °C
Lower non-critical
1 °C
n.a.
1 °C
-5 °C
Lower critical
n.a.
n.a.
n.a.
-7 °C
Lower non-recoverable
n.a.
n.a.
n.a.
-10 °C
Table 12: Thresholds - Extended Temperature Range
Sensor Number /
ID string
0Eh /
A1:Temp
CPU
0Fh /
A1:Temp
PCH
10h /
A1:Temp
MCH
16h /
A1:Temp
Air
Upper non-recoverable
115 °C
116 °C
110 °C
100 °C
Upper critical
105 °C
111 °C
100 °C
95 °C
Upper non-critical
95 °C
101 °C
90 °C
85 °C
Normal max.
90 °C
96 °C
85 °C
80 °C
Nominal
80 °C
86 °C
75 °C
70 °C
Normal min.
3 °C
3 °C
3 °C
0 °C
Lower non-critical
1 °C
n.a.
1 °C
-40 °C
Lower critical
n.a.
n.a.
n.a.
-42 °C
Lower non-recoverable
n.a.
n.a.
n.a.
-45 °C