beautypg.com

1 ipmb-l link sensor, 2 module hot swap – Kontron AM4301 User Manual

Page 20

background image

8

AM4301

www.kontron.com

X

Exceed critical threshold

*

Power On/Off

-

Power On

N

No change

**

The lower limits are not asserted; only the upper limits (non-critical, critical and non-
recoverable) are asserted for temperature sensors.

2.4.2.1

IPMB-L Link Sensor

The AM4301 has an IPMB-L links to communicate with the AMC Carrier and other chassis devices on the
chassis IPMB-0 bus. MMC monitors the bus for any link failure and send the bus failure event to the AMC
Carrier upon the recovery occurs.

2.4.2.2

Module Hot Swap

The hot-swap event message conveys the current state of the module, the previous state, and a cause of the
state change as can be determined by the MMC. Refer to AMC.0 R1.0 Specifications for further details on the
module hot-swap state.

PexLaneGood 5

PCIE lane 5 detection

-

N

PexLaneGood 6

PCIE lane 6 detection

-

N

PexLaneGood 7

PCIE lane 7 detection

-

N

PexLaneGood 8

PCIE lane 8 detection

-

N

PexLaneGood 9

PCIE lane 9 detection

-

N

PexLaneGood A

PCIE lane 10 detection

-

N

PexLaneGood B

PCIE lane 11 detection

-

N

PexLaneGood C

PCIE lane 12 detection

-

N

PexLaneGood D

PCIE lane 13 detection

-

N

PexLaneGood E

PCIE lane 14 detection

-

N

PexLaneGood F

PCIE lane 15 detection

-

N

Health Error

Board health sensors (aggregation of other sensors)

*

Asserted /

Desserted

MMC Reboot

IPMC reboot detection

*

N

Ver change

IPMC firmware upgrade detection

*

N

Sensor Name

Voltage/Signals Monitored

Scanning Enabled
under Power
State

Health LED
(Green to Red)