2 power distribution, Power distribution - 15, 14 power connector (p10) - 15 – Kontron AT8901 User Manual
Page 46: At8901 hardware description
AT8901
Hardware Description
Page 3 - 15
AT8901 User Guide
3.7.2
Power Distribution
The 48 Volts are supplied by the backplane via two independent rails, primary (A) and second-
ary (B). The rails are mixed using power Schottky rectifiers. A 7A fuse protects each -48V line
and a 10A fuse protects each RTN line. A hot swap controller enables the 48V power to the
board.
A quarter brick DC/DC converter transforms the 48 Volts to secondary 12 Volts, which are dis-
tributed on the board. The converter allows a maximum of 14A output current.
Two different management voltages (3.3V and 5V) and five payload voltages (3.3V, 2.5V, 1.8V,
1.25V and 1.2V) are generated by point of load converters. These are either switches or linear
regulators.
Table 3-14: Power Connector (P10)
Signal
Pin
Pin
Signal
N.C.
1
2
N.C.
N.C.
3
4
N.C.
HA0
5
6
HA1
HA2
7
8
HA3
HA4
9
10
HA4
HA6
11
12
HA5
SCL_A
13
14
SDA_A
SCL_B
15
16
SDA_B
MT1_TIP(N.C.)
17
18
MT2_TIP(N.C.)
RING_A(N.C.)
19
20
RING_B(N.C.)
MT1_RING(N.
C.)
21
22
MT2_RING(N.
C.)
RRTN_A(N.C.)
23
24
RRTN_B(N.C.)
SHELF_GND
25
26
LOGIC_GND
ENABLE_B
27
28
VRTN_A
VRTN_B
29
30
EARLY_A
EARLY_B
31
32
ENABLE_A
-48V_A
33
34
-48V_B
4
16
20
24
26
28
32
31
34
1
13
25
29
27
30
33
17
21