3.3

AMC Bays

Two AMC bays for standard or custom AMCs with full height and single width are implemented
with B+ connectors.

Following AMC Geographic Addresses are implemented:

Table 3-9: AMC Bay Address

The state of each GA signal is represented by G (grounded), U (unconnected) or P (pulled up
to management power).

AMC

AMC Bay ID

GA [2..0]

IPMB-L Address

1

B1

UGU

7Ah

2

B2

UUG

7Ch

Table 3-10: AMC B1 Channel Assignment

Channel

Region

Connection

0

GbE

Local Base Switch 0/21

1

GbE

Remote Base Switch 0/22

2

SATA/FC

AMC B2, channel 2

3

SATA/FC

RTM, STOR0

4

Fabric

-

5

Fabric

-

6

Fabric

-

7

Fabric

-

8

Fabric

-

9

Fabric

-

10

Fabric

-

11

Fabric

-

12

-

-

13

Extended

RTM, AMC_B1_P13

14

Extended

RTM, AMC_B1_P14

15

Extended

RTM, AMC_B1_P15

16

Extended

RTM, AMC_B1_P16

17

Extended

RTM, AMC_B1_P17

18

Extended

RTM, AMC_B1_P18

19

Extended

RTM, AMC_B1_P19

20

Extended

RTM, AMC_B1_P20