beautypg.com

Defiant 1610 non-catalytic woodburning stove – Vermont Casting 1610 User Manual

Page 17

background image

17

Defiant 1610 Non-Catalytic Woodburning Stove

30002850

48"

(1220 mm)

48"

(1220 mm)

48"

(1220 mm)

ST498

Defiant

Wall shield B

11/00

Fig. 17 Parallel installation with rear wall pass-through, two
wall shields. Reduced clearances to both rear and side walls.
Wall shields may meet at corner if desired. Wall pass-through
must comply with codes.
Refer to “Special Installations.”

ST498

48"

(1220 mm)

48"

(1220 mm)

48"

(1220 mm)

48"

(1220 mm)

ST497

Defiant

wall shield A

11/00

Fig. 16 Parallel installation, vertical chimney connector, two
wall shields. Reduced clearances for both rear and side walls.
Wall shields may meet at corner if desired. Shielding for con-
nector is centered behind connector.

ST497

Refer to

IMPORTANT

Note on This

Page

48"

(1220 mm)

48"

(1220 mm)

48"

(1220 mm)

48"

(1220 mm)

ST499

Defiant

Wall Shield C

11/00

ST499

Fig. 18 Corner installation, vertical chimney connector, two
wall shields. Reduced side clearances. Wall shield MUST
meet at corner.

Refer to

IMPORTANT

Note on This

Page

Refer to

IMPORTANT

Note on This

Page

IMPORTANT: when the stove is installed with 8” con-
nector pipe, wall shields must extend to within 1” (25
mm) of the ceiling (up to 9’ (2.7 m)) due to potentially
higher pipe temperatures. With 6” connections, the wall
shields only need to extend to a height of 48” (1220
mm) as shown in the grey shaded areas of Figures 16,
17 and 18.