Just Better Zeppelin 2-valve Brass and Aluminum Manifol User Manual
Directions for use, For professional use only, Limited warranty
Directions For Use
C
A
B
D
E
EVAPORATOR
COMPRESSOR
CONDENSER
RECEIVER
MANIFOLD
COMPRESSOR
A
B
C
D
E
Charging and
Discharge
Suction
Low Side
High Side
Evacuation Port
Service Valve
Service Valve
Blue
Red
Yellow
Red
Blue
To Observe
Closed
Closed
Back Seated
Back Seated &
Operating Pressures
& Cracked Open
Cracked Open
To Charge Refrigerant
Open
Closed
Connect Line
Back Seated
Front Seated
Through Suction Valve
to Refrigerant Supply
& Cracked Open
To Charge Oil
Open
Closed
Connect Line
Back Seated
Front Seated
Through Suction Valve
To Oil Supply
To Charge Liquid Refrigerant
Closed
Open
Connect Line
Midway Open
Through Discharge Valve
To Refrigerant
To Build Low Pressure;
Open
Open
Refrigerant
Back Seated
Midway Open
For Control Setting
Line Closed
& Cracked Open
Or Leak Detecting
To Purge Refrigerant
Closed
Open
Refrigerant
Back Seated
From Discharge Valve
Line Open
& Cracked Open
To Evacuate With
Open
Open
Connect To
Midway Open
Midway Open
Auxiliary Vacuum Pump
Vacuum Pump
Caution: Always consult
equipment manufacturer's
service manual or instruc-
tion sheet for recommended
procedures.
FOR PROFESSIONAL USE ONLY
JB manifolds are designed for use by technically trained
AC/R service engineers only. Due to the high pressures encoun-
tered in all systems that this manifold will be used on, plus the
dangers due to the physical and chemical nature of refrigerants
and oils present in all systems, misapplication could result in
injury or death.
LIMITED WARRANTY
Manifold bar has a lifetime warranty, while the components, i.e.
gauges, hoses, handles, hose holders, etc. are covered under
the limited warranty policy. Products are warranted for a period
of one year from date of shipment by JB and limited to repair,
replacement or credit, if in our opinion are defective due to
workmanship and/or materials. Defective components should be
returned to the wholesaler from which the product was pur-
chased for evaluation.
Manifolds are designed for use with all refrigerants except
ammonia (R-717). Working pressures are limited to gauge dial
range. Use of this manifold under any other conditions voids the
warranty.
FORM NO. 23000-308
PRINTED IN U.S.A.