4 valve manifold instructions2.pdf, Directions for use, For professional use only – Just Better Zeppelin 4-valve Manifold User Manual
Page 2: Limited warranty
Directions For Use
Caution: Always consult
equipment manufacturer's
service manual or instruc -
tion sheet for recommended
procedures.
A
C
D
B
F
E
MANIFOLD
COMPRESSOR
A
B
C
D
E
F
Evacuation
Charging
Discharge
Suction
Low Side
High Side
Port
Port
Service Valve
Service Valve
Blue
Red
Black
Yellow
Red
Blue
To Observe
Closed
Closed
Closed
Closed
Back Seated
Back Seated
Operating Pressures
& Cracked Open
& Cracked
To Charge Refrigerant
Open
Closed
Closed
Open
Back Seated
Front Seated
Through Suction Valve
& Cracked Open
To Charge Oil
Open
Closed
Open
Closed
Back Seated
Front Seated
Through Suction Valve
To Charge Liquid Refrigerant
Closed
Open
Closed
Open
Midway Open
Through Discharge Valve
To Build Low Pressure;
Open
Open
Closed
Closed
Back Seated
Midway Open
For Control Setting
& Cracked Open
Or Leak Detecting
To Purge Refrigerant
Closed
Open
Closed
Open
Back Seated
From Discharge Valve
& Craked Open
To Evacuate With
Open
Open
Open
Closed
Midway Open
Midway Open
Vacuum Pump
EVAPORATOR
CONDENSER
RECEIVER
COMPRESSOR
FOR PROFESSIONAL USE ONLY
JB manifolds are designed for use by technically trained
AC/R service engineers only. Due to the high pressures
encountered in all systems that this manifold will be used on,
plus the dangers due to the physical and chemical nature of
refrigerants and oils present in all systems, misapplication
could result in injury or death.
LIMITED WARRANTY
Manifold bar has a lifetime warranty, while the components,
i.e. gauges, hoses, handles, hose holders, etc. are covered
under the limited warranty policy. Products are warranted for
a period of one year from date of shipment by JB and limited
to repair, replacement or credit, if in our opinion are defective
due to workmanship and/or materials. Defective components
should be returned to the wholesaler from which the product
was purchased for evaluation.
Manifolds are designed for use with all refrigerants except
ammonia (R-717). Working pressures are limited to gauge
dial range. Use of this manifold under any other conditions
voids the warranty.
FORM NO. 25000-308
PRINTED IN U.S.A.