Prowler specifications – Just Better LD-5000 Prowler Leak Detector User Manual
Page 7
PROWLER SPECIFICATIONS
Model #:
LD 5000
Name:
PROWLER Leak Detector, Refrigerant Gas
Sensitivity:
0.025 oz/yr R-22, 0.05 oz/yr R-134a,
0.0125 oz/yr R-1234yf, 0.05 oz/yr R-410A,
0.05 oz/yr R-404A,
0.05 oz/yr R-407A,
0.05
oz/yr
R-427A
Sensor Life:
> 10 years (normal use)
Response Time:
Instantaneous
Power Supply:
4 AA Alkaline batteries
Battery Life:
4.5 hours continuous
Warm Up Time:
< 20 seconds
Probe Length:
17”
LCD Display:
Sensitivity, Battery Light, Leak Level Indication
Weight, lbs.:
1lb. 3.4 oz.
Warranty:
2 years includes sensor
EN 14624 TEST SPECIFICATIONS
Min/Max Sensitivity
1 gm/yr minimum, > 50 gr/yr maximum
Threshold (fi xed):
Min/Max Sensitivity
3 gm/yr minimum, > 50 gm/yr maximum
Threshold (moving):
Min Detection Time:
Approximately 1 second
Clearing Time:
Approx. 9 seconds after exposure to > 50 gm/yr
Min. Threshold after
Maximum Exposure:
1 gr/yr
Sensitivity Threshold in
Polluted Atmosphere: 1 gm/yr
Calibration Frequency: 1/yr check with calibrated leak Standard