beautypg.com

ISSPRO R82522 User Manual

Performax

background image

PERFORMAX

Form No. IS159 (Rev. A 03/11/2008

)

ISSPRO, INC.

2515 N.E. Riverside Way

Post Office Box 11177

Portland, Oregon 97211-1899

503-288-4488

800-888-8065

Fax: 503-249-2999

www.isspro.com

© 2008 ISSPRO, Inc. All Rights Reserved.


TRANSMISSION PRESSURE GAUGE AND SENSOR
INSTALLATION INSTRUCTIONS

Models: R43244 R52244 R53244 R59244 R68244 R69244 R82244

1



Disconnect batteries. Do not reconnect battery power until system is

fully configured to avoid risk of shock or fire.

2

Install Electronic Signal Processor (ESP) and ESP harness according to

instructions.

I C O N K E Y

CAUTION

Tools may be required

Shown in picture

3



Connect the Temperature Sensor Harness to the ESP Harness as follows:

a. Remove plugs from cavities 10, 11 and 12 of the connector C (green) of the ESP.
b. Using a pair of needle nose pliers, pull the orange wedge lock out of connector C.
c. Insert the terminal from the red wire (5V sensor supply output) into cavity 10 of connector C

on the ESP, pushing until it snaps into connector C.

d. Insert the terminal from the black wire (sensor supply ground) into cavity 11 of connector C

on the ESP, pushing until it snaps into connector C.

e. Insert the terminal from the green wire into cavity 12 (sensor input) of connector C on the

ESP, pushing it until it snaps in place.

f. Note: Terminals will be close to flush with the top of the connector when fully seated.
g. A firm pull of the wire will confirm whether they are properly seated.
h. Push the orange wedge lock back into position. If any of the wires are not fully seated, the

wedge lock will not insert into position.

i. Reconnect connector C (green) to the ESP.

Figure

1: Connector C top and bottom

view. Shown with plugs and wedge-lock
installed.

Figure 2: Remove plugs and wedge-lock as
shown. Wedge-lock is replaced once wires are
positioned properly.




This manual is related to the following products: