AIR PRESSURE GAUGE AND SENSOR INSTALLATION
INSTRUCTIONS
Models: R43266 R52266 R53266 R59266 R68266 R69266 R82266
1
Disconnect batteries. Do not reconnect battery power until system is
fully configured to avoid risk of shock or fire.
2
Install Electronic Signal Processor (ESP) and ESP harness according to
instructions.
I C O N K E Y
CAUTION
Tools may be required
Shown in picture
3
Connect the Temperature Sensor Harness to the ESP Harness as follows:
a. Remove plugs from cavities 3, 11 and 12 of the connector D (brown) of the ESP.
b. Using a pair of needle nose pliers, pull the orange wedge lock out of connector D.
c. Insert the terminal from the red wire (5V sensor supply output) into cavity 3 of connector D
on the ESP, pushing until it snaps into connector D.
d. Insert the terminal from the green wire (sensor input) into cavity 11 of connector D on the
ESP, pushing until it snaps into connector D.
e. Insert the terminal from the black wire (sensor supply ground) into cavity 12 of connector D
on the ESP, pushing until it snaps into connector D.
f. Note: Terminals will be close to flush with the top of the connector when fully seated.
g. Press the orange wedge lock back into the brown connector.
h. A firm pull of the wire will confirm whether they are properly seated.
i. Push the orange wedge lock back into position. If any of the wires are not fully seated, the
wedge lock will not insert into position.
j. Reconnect connector D (brown) and any other disconnected connectors to the ESP.
Figure
1: Connector D top and bottom
view. Shown with plugs and wedge-lock
installed.
Figure 2: Remove plugs and wedge-lock as
shown. Wedge-lock is replaced once wires are
positioned properly.