TECHNICAL INFORMATION
HEATER GUARD
PRE-SEDIMENT AND SCALE PROTECTION FOR WATER HEATERS
MODEL #s: EWS-HEATER-GUARD-3/4 and EWS-HEATER-GUARD-1.5
EITHER MODEL CAPABLE OF REVERSIBLE INSTALLATION
SYSTEM SPECIFICATIONS
OPERATION TEMPERATURE:
Maximum 100
o
F (38
o
C) / Minimum 40
o
F (4
o
C)
OPERATION PRESSURE:
Standard working pressure maximum 75 psi / minimum 30 psi
INLET/OUTLET FOR HEATER GUARD 3/4:
3/4”
INLET/OUTLET FOR HEATER GUARD 1.5:
1 1/2”
DIMENSIONS OF HEATER GUARD 3/4:
25 3/4” x 5 1/4”
DIMENSIONS OF HEATER GUARD 1.5:
29” x 7 1/2”
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
Replace your filter annually or as needed (do not exceed 1 year). Install in cold water applications only [installs inline prior to the water
heater(s)]. Install in compliance with local and state regulations.
All installation instructions, service manuals, technical and product information is available online at www.EWSWATER.com
FILTER SPECIFICATIONS
ITEM #: BB-GUARD-FILTER-3/4
DESCRIPTION:
20” Pre-Sediment (5 Micron) for the Heater Guard 3/4”
PURPOSE:
Filters out rust, silt, and sediment and inhibits scale formation in water heaters.
FEATURES & BENEFITS:
Enhances performance of water heaters, prevents costly repairs.
CONSTRUCTION:
100% FDA-approved food-grade polyphosphate.
SERVICE LIFE:
1 year Filter service life is based on local water conditions and usage and should be replaced as needed, not to exceed one year. ‡
MAX. FLOW:
9.5 GPM / 36 LPM
MAX. PRESSURE:
75 PSIG / 5.17 Bar
TEMPERATURE RANGE:
40-100
o
F / 4-38
o
C
ITEM #: BB-GUARD-FILTER-1.5
DESCRIPTION:
20” Pre-Sediment (5 Micron) for the Heater Guard 1.5”
PURPOSE:
Filters out rust, silt, and sediment and inhibits scale formation in water heaters.
FEATURES & BENEFITS:
Enhances performance of water heaters, prevents costly repairs.
CONSTRUCTION:
100% FDA-approved food-grade polyphosphate.
SERVICE LIFE:
1 year Filter service life is based on local water conditions and usage and should be replaced as needed, not to exceed one year. ‡
MAX. FLOW:
20 GPM / 75.7 LPM
MAX. PRESSURE:
75 PSIG / 5.17 Bar
TEMPERATURE RANGE:
40-100
o
F / 4-38
o
C
MODEL #
REPLACEMENT FILTER ITEM #
EWS-HEATER-GUARD-3/4 BB-GUARD-FILTER-3/4
EWS-HEATER-GUARD-1.5
BB-GUARD-FILTER-1.5
SERVICE LIFE ON FILTERS:
UP TO 1 YEAR.* REPLACE YOUR
FILTERS ANNUALLY OR AS NEEDED.
DO NOT EXCEED 1 YEAR.
This filter element tested
and certified under ANSI/
NSF Standard 42 for
materials only.
COMPONENT
1. EWS Series. Inhibits scale formation and protects the
entire home and family from the health side-effects
and corrosiveness of chlorine, chloramine, VOCs,
THMs, and much more.
2. Heater Guard. Protects water heaters at the inlet.
Combined with an EWS system, it is the perfect
application for healthy, hassle-free water to the
whole home.
3. Softener. Will inhibit scale formation, however, the
water becomes aggressive and may have long-term
corrosive effects on your water heater.
CALL EWS CUSTOMER SERVICE: 702.256.8182 (MONDAY-FRIDAY 8.30 AM-4.30 PM PACIFIC TIME)
FAX: 702.256.3744 EMAIL: [email protected]
W W W . E W S W A T E R . C O M
HEATER GUARD 3/4” SHIPPING DETAILS
SHIPPING CARTON SIZE:
8” W x 8” D x 28” H
SHIPPING CARTON WEIGHT:
7 lbs.
HEATER GUARD 1.5” SHIPPING DETAILS
SHIPPING CARTON SIZE:
9” W x 9” D x 31” H
SHIPPING CARTON WEIGHT:
14 lbs.
Pictured at Right:
The
HEATER GUARD 1.5
.
Ideal for 1 1/2” plumbing line
sizes. Select this model if the
home’s inlet to the heater has
a 1 1/2” or greater line size,
or requires greater flow rate.
Mounting bracket and gauge
are reversible.
Fully Compliant
with California
No-Lead Standards.
3 BEST WAYS TO PROTECT YOUR HEATER
1
Under no circumstances does
the EWS Heater Guard change
or alter the proper application
and/or routine maintenance
required or recommended by the
manufacturer of any product.
‡The filter gauge is based
on a pressure differential. It
can only be observed while
water is flowing through the
Heater Guard and will only
move when filter cartridge has
been prematurely clogged or
restricted. The gauge is only a
precaution to prevent problems.