Removing the handle, Cable repair fittings – Electric Eel RF User Manual
Page 13
![background image](/manuals/636187/13/background.png)
Model RF Manual (082610)_2-ColorREV.doc
Page
13 of 16
9. Remove shaft out of the back of
the machine to allow cage to be
removed. (See Figure #16)
Figure 16
10. Reverse the above
procedure to reinstall the
cable cage.
REMOVING THE HANDLE
The handle can be removed from the
machine for compact storage of unit or
for work in crawl spaces by backing off
the two thumb screws. When
replacing the handle, be sure the
thumb screw tips engage in the
corresponding holes in the handle.
CABLE REPAIR FITTINGS
The following fittings are used for
cable repair.
1. SP-30 Tool Adapter
2. SP-32 Female Fitting 3/4” Cable
SJ-32 Female Fitting 5/8” Cable
3. SP-31 Male Fitting 3/4” Cable
SJ-31 Male Fitting 5/8” Cable
4. RP 1434 Roll Pin 3/4” Cable
RP 1458 Roll Pin 5/8” Cable
1
2
3
4