beautypg.com

EFCO S5900 Outside Glazed User Manual

Page 5

background image

EFCO CORPORATION 6/2012 PART NO. Y350

Page 5 of 16

Series 5900 Outside Glazed Curtain Wall Installation Instructions

Section II: Perimeter Application

Perimeter Application

A.)

For anchoring to perimeter and providing a spacer for glazing pockets at head,
jamb, and sill.




Note: Anchoring surfaces of perimeter constructions must be level and plumb

within the adjustments of the head, jamb, or sill. See “APPROVED” shop
drawings for adjustment limits.

Fill gasket race with sealant in top

bottom of each vertical mullion to

marry with perimeter sealant.

Pressure Plate

with return

CRITICAL

SEAL LINE

Primary seal

Optional

cosmetic seal

Top anchor is recommended

at head connection to

accommodate thermal

movement.

“M” Anchor

Line of critical

perimeter

sealant shown

Size and locate

anchor bolts in the

field, based on job

conditions and
structural load

requirements.

½” Nominal.

(3/8” Minimum)

Erector to supply and

apply bond breaker tape
across face of anchor to

prevent 3-sided sealant

adhesion.

“M” Anchor

“F” Anchor

Perimeter With Continuous Pocket Filler

Mullion Anchors

Note: The perimeter caulking must be done prior to glazing. Reference the

“APPROVED” shop drawings for caulk joint size unless otherwise specified.
Most sealant manufacturers recommend a 3/8” minimum joint width.