Code 3 XP 9500 User Manual
Page 5
![background image](/manuals/635413/5/background.png)
5
LED MODULES
The LED modules are available as “flashing” and “stationary” versions. The stationary versions can
be flashed by connecting the module(s) to any flasher that does not require ground through the load
(example: Code 3® 925 or 700 series relay flasher). The flashing modules will have "Cycleflash"
as the standard pattern. Flash patterns can be changed by shorting the 2-pin header, J1 as shown
in Figure 3, momentarily then releasing. Table 1 shows the available patterns and the order when
stepping through patterns. The module can be reset to "Cycleflash" by shorting the header for
greater than 5 seconds and releasing.
FIGURE 3
Directional Module Flash Pattern - Table 1
Flash Pattern
Description
Cycle Flash
Cycles through various patterns @ 70 fpm
Steady-Burn
Steady-Burn
Five Flash
Five Pulses per flash @ 70 fpm
Quad Flash
Four Pulses per flash @ 70 fpm
Triple Flash
Three Pulses per flash @ 70 fpm
Double Flash
Two Pulses per flash @ 70 fpm
Fast Double Flash
Two Pulses per flash @ 85 fpm
NFPA
Four Pulses, 70% Duty Cycle @ 75 fpm
Quad Pop Flash
Four Pulses per flash ( 3 equal, 1 extended) @ 70 fpm
Triple Pop Flash
Three Pulses per flash ( 2 equal, 1 extended) @ 70 fpm
J1
PCB
Momentarily short and release
to change patterns