Led flash pattern selection, Maintenance, Warning – Code 3 Torus Lighthead User Manual
Page 7
WARNING!
7
6-LED Flash Pattern Selection
This unit will provide up to twenty one different flash modes. Each of
these modes can be selected by grounding and releasing the white wire.
As each flash mode is selected it is automatically programmed into the
unit such that when power is removed it will always return to the selected
mode the next time power is applied.
Maintenance:
The Exterior LED Modules are completely sealed units designed to be
trouble and maintenance free. Refer to the guide below for help with
troubleshooting. Should the unit be diagnosed as malfunctioning, remove
unit and replace with a new module.
TROUBLESHOOTING
Problem
Probable Cause
Remedy
Lighthead does not
activate
a. No Power to unit
b. Power input wire
reversed
c. Damaged or shorted
cabling
d. Defective Lighthead
e. Control wire permanently
grounded or shorted to
GND
a. Check wiring for
loose connection
b. Reverse Power wires
c. Check cables for
damage
d. Replace lighthead
module
e. Avoid permanent
grounding of control
wire
Lighthead is con-
stantly ON
a. Control wire permanently
grounded or shorted to GND
6-LED Flash Modes:
Alternating
Simultaneous Steady with Flashing
Cycle Flash
Quad Flash
Fast Double Flash w/Steady
Single Flash
Triple Flash
Quad Flash w/Steady
Double Flash
Double Flash
Triple Flash
Single Flash
Quad Flash
Pursuit Flash
Five Flash
Fast Single Flash
Fast Double Flash
Fast Triple Flash
Fast Quad Flash
Quad Pop Flash
Triple Pop Flash
Double Pop Flash
Wig-Wag Flash Alt.
Note: All modes flash at a rate of 70 fpm minimum. Fast modes flash at a rate of 100 fpm
minimum.
WARNING!
LED module housings may become hot with ex-
tended use. Allow modules to cool completely before
attempting to remove.