beautypg.com

Wiring instructions, Warning, Warning! tricore lighthead flash pattern – Code 3 SuperVisor with TriCore for Ford Crown Victoria User Manual

Page 5

background image

Larger wires and tight connections will provide longer service life for components. For high current wires it

is highly recommended that terminal blocks or soldered connections be used with shrink tubing to protect

the connections. Do not use insulation displacement connectors (e.g. 3M

®

Scotchlock type connectors).

Route wiring using grommets and sealant when passing through compartment walls. Minimize the number

of splices to reduce voltage drop. High ambient temperatures (e.g. underhood) will significantly reduce the

current carrying capacity of wires, fuses, and circuit breakers. Use "SXL" type wire in engine compartment.

All wiring should conform to the minimum wire size and other recommendations of the manufacturer and

be protected from moving parts and hot surfaces. Looms, grommets, cable ties, and similar installation

hardware should be used to anchor and protect all wiring. Fuses or circuit breakers should be located

as close to the power takeoff points as possible and properly sized to protect the wiring and devices.

Particular attention should be paid to the location and method of making electrical connections and splices

to protect these points from corrosion and loss of conductivity. Ground terminations should only be made

to substantial chassis components, preferably directly to the vehicle battery. The user should install a

fuse sized to approximately 125% of the maximum Amp capacity in the supply line to protect against

short circuits. For example, a 30 Amp fuse should carry a maximum of 24 Amps. DO NOT USE 1/4"

DIAMETER GLASS FUSES AS THEY ARE NOT SUITABLE FOR CONTINUOUS DUTY IN SIZES ABOVE

15 AMPS. Circuit breakers are very sensitive to high temperatures and will "false trip" when mounted in hot

environments or operated close to their capacity.

wARNINg!

wiring Instructions

5

wiring Diagram and Flash Pattern Changes - NO TAKEDOwNS

It is advisable to leave an extra loop of cable when installing the lightbar to allow for future changes or reinstallations.

Connect the black lead to a solid frame ground (earth), preferably the (-) or ground (earth) side of the battery, and the

power wire to the +12V terminal of the battery. Connect the remaining wires as shown below.

NOTE: FOR SUPERVISORS WITH TAKE DOWN OPTION SEE DIAGRAM ON NEXT PAGE

FUSE WITH CUSTOMER SUPPLIED 10 AMP FUSE

GREEN (PATTERN SELECT)

WHITE (DIMMING)

RED (POWER)

YELLOW (LEVEL 3)

ORANGE (LEVEL 2)

BLUE (LEVEL 1)

BLACK (GND)

This Product contains high intensity TriCore devices. To prevent eye damage,

DO NOT stare into light beam at close range.

wARNINg!

TriCore Lighthead Flash Pattern

To change the flash patterns of the TriCore Lightheads, activate the Lightbar in Level 1 and then momentarily

touch the green (Pattern Select) wire to +power. Repeating this procedure allows the operator to cycle through the

numerous flash patterns offered until the desired pattern is achieved.

To reset the flash patterns to the factory default, activate the Lightbar in Level 1 and then hold the Green (Pattern

Select) wire to +power for approximately 4 seconds.

For table of flash patterns see next page.