RECOMMENDED MINIMUM WIRE SIZES
BASED ON 15-FOOT WIRE RUN
AMP DRAW
MIN. WIRE SIZE
Below 5
#18 AWG
5-8
#16 AWG
9-13
#14 AWG
14-21
#12 AWG
22-36
#10 AWG
NOTE: Larger wires and tight connections will provide longer service life for
switches and improve lighting performance. High ambient temperatures
(e.g. under hood) will significantly reduce the current carrying capacity of wires,
fuses and circuit breakers.
PARTS AND SWITCHES
SPST Single Pole, Single Throw switch; controls a single circuit.
SPDT Single Pole, Double Throw switch; controls either one or two circuits.
DPST Double Pole, Single Throw switch; high amperage single circuit.
DPDT Double Pole, Double Throw switch; for radio rebroadcast.
Radio Rebroadcast Transfers radio messages to siren speaker.
Momentary Remains active only while held, springs back to OFF.
Progressive Turns two functions on or off in a set sequence.
NUMBER
TYPE
APPLICATION
POSITIONS
LIGHTED
RATING
T02811
SPST
Single circuit
OFF-ON
YES
20 amp
T02812
SPDT
Alternate circ.
ON-OFF-ON
YES
20 amp
T02813
SPST
Momentary
OFF-MomON
NO
8 amp
T02814
Blank
Fills hole
NO
T02815
SPDT
Moment/Moment
ON-OFF-ON
NO
8 amp
T02820
-
Red Indicator Light
YES
-
T02821
DPST
High Amperage
OFF-ON
YES
40 amp
T02822
SPDT
StringRay switch
ON-OFF-0N
NO
20 amp
T02823
DPDT
Radio Rebroadcast
ON-ON
NO
8 amp
T02824
PROG
Progressive
OFF-ON-ON
YES
20 amp
T02838
Auto Reset Circuit Breaker
-
40 amp
T02871
Push Button Switch (415T only) OFF-ON
NO
1 amp
T02872
Actuator Disk (PTO unit only)
S38033
Fuse Stack (Factory Upgradecannot be field installed)
S38046
Backlighting Assembly (Bulbs with wires only)
S38049
Backlighting Assembly (Complete)
S38093
Floor-mounting Bracket, PTO Control
S25013
RockerPak Mounting Bracket (2 required)
Parts not listed should be purchased locally