Operation, Maintenance, Warning – Code 3 Quadrant LED Mini Bar User Manual
Page 3: Flash patterns, Setting the flash pattern
3
This product contains high intensity LED devices. To prevent eye damage, DO NOT stare ino light beam
at close range.
This product contains high intensity LED devices. To prevent eye damage, DO NOT stare
into light beam at close range.
WARNING!
Current:
Default Flash Current (Ave):
<2.0 Amps @ 13.8VDC
Operation
Flash Patterns:
The Quadrant LED Beacon is programmed with 19 different flash patterns. Refer the section below for instructions on how to
set the flash pattern.
1
Single flash 75 sim all flash (factory Default)
2
ECE R65 120FPM single flash
3
CA T13 75FPM single flash
4
Double flash 75 sim all flash
5
Swiftflash flash 75 sim all flash
6
Quad Flash 75 sim all flash
7
Single Flash 75 center-split
8
Single Flash 75 clockwise
9
Single Flash 75L clockwise
10
NFPA 75FPM Quad Flash
11
Five Flash sim all
12
Modu flash sim all
13
ECE R65 Double Flash
14
125FPM Rotating Flash
15
Single Flash 120 center-split
16
Single Flash 120 clockwise
17
Single Flash 120L clockwise
18
Three Flash 120 sim all flash
19
Cycle Flash
20
OFF (For Reference only. This flash pattern cannot be stored in
the beacon's memory)
Setting the Flash Pattern:
To change the flash pattern, d
epress the push-button switch on the lighter plug for -
- Less than 1 second for the NEXT pattern
- 1 to 3 seconds for the PREVIOUS pattern
- 3 to 5 seconds for the DEFAULT pattern
- Greater than 5 seconds to TURN OFF the beacon
Maintenance:
The beacons are completely sealed units designed to be maintenance free. Refer to the guide below for help
with troubleshooting. Should the unit be diagnosed as malfunctioning, remove unit and replace with a new
beacon.
TROUBLESHOOTING
Problem
Probable Cause
Remedy
Beacon does not activate
a. No power to unit
a. Check Lighter Plug for loose
connection
b. Damaged or shortaged cabling b. Check cables for damage
c. Defective Beacon
c. Contact Service Dept.