Troubleshooting, Maintenance, Warning – Code 3 Astro L800, Star LL400, Nova L200 User Manual
Page 6
6
Troubleshooting
PROBLEM
PROBABLE CAUSE
REMEDY
a.) Unit power leads hooked up backwards.
b.) Output capacitor shorted.
c.) Flashtube worn.
d.) Flashtube polarity backwards
a.) Fuse not proper ampere rating.
b.) Wiring to unit shorted.
c.) Power supply failure.
a.) Flashtube worn.
b.) Output capacitor worn.
c.) Jumpers in wrong position (variable
flash only).
No Output
External Fuse Blows
Improper Flash Pattern
a.) Reverse power leads.
b.) Return for service.
c.) Replace flashtube.
d.) Reverse flash tube.
a.) Replace with proper sized fuse.
b.) Replace wiring to unit.
c.) Return for service.
a.) Replace flashtube.
b.) Return unit for service.
c.) Reset jumpers (variable
flash only).
Strobe lamps are extremely hot! Allow to cool completely before attempting to remove.
Gloves and eye protection should be worn when handling strobe flashtubes as they are
pressurized and accidental breakage can result in flying glass. High voltages and/or
temperatures are present inside of strobe units. Disconnect from power and wait 10
minutes prior to servicing.
WARNING!
!
Maintenance
The Flash Series strobes have a field replaceable Xenon flashtube. (See parts list for part numbers) The
flashtube snap mounts onto the printed circuit board. Care should be taken to ensure that the tube holder
guide pins are inserted into the printed circuit board and that the base of
the tube holder is flush with the printed circuit board. Do not remove the circuit board from the base. Service
the unit in dry locations. CAUTION: Unit contains high voltages and high temperatures, disconnect from
power and wait 10 minutes before servicing.