On/off: Plug in the power, there is a beep sound, and the machine comes to the

standby mode. Once press this button, the machine start to work with LED display on.
Press this button again, the machine stops working and come to the standby mode.

Timer: Timer or no-timer function for your choose by pressing this key, Timer can

be from 1-12 hours

AUTO: Press this button, the machine enter an automatic control mode. the device

will choose suitable humidifying level as per environmental humidity and maintains the
humidify between 55% - 65%.

Mist Volume: Cool mist steam volume can be changed amount 1 estate, 2 estate,

3 estate by pressing this key . Smallest steam for 1 estate, biggest steam for 3 estate

Set Humidity: Humidity can be increased from 40% to 80% at every 5% .

Machine will check around humidity automatically when turn on

Constant humidity: The machine will be control humidity automatically when set a
humidity, For example, Just like set a humidity 50%, The machine will check around
humidity to see if it has reached 50%, Less than 50%, machine keep working, Equal to
50% or above, Machine stop working, Ensure the humidity keep at a stable situation.

When turn on the device, the machine will start to work for 1 minutes no matter if the
around humidity reaches the set humidity or not.

Warm Mist: This is button is used to adjust the estate of warm mist, there are 4

estates, max, med, min and off . When the warm mist function is off, the machine only
works with cool mist .

Please note

► The device shall automatically after switch the humidity in the room.
► In a neighborhood with 45% to 60% humidity people feel at ease.
► Make a humidity of 50%, for example, the device checks the ambient humidity. It works

until a humidity of 50% is achieved and maintains this value stable.