Appendix a: alarm i/o connector – AVer SF1311H-D User Manual
Page 52
48
Appendix A: Alarm I/O Connector
Some features of the Camera can be activated by the external sensor that senses physical
changes in the area Camera is monitoring. These changes can include intrusion detection or
certain physical change in the monitored area. For examples, the external sensor can be a door
switch or an infrared motion detector. These devices are customer provided, and are available
from dealers who carry surveillance and security products. Electrically, they must be able to
provide a momentary contact closure.
This Camera provides wires for general I/O terminal and RS485 interface as below:
Cable for I/O connectors:
Name
Cable Color
Function
12VDC
Brown/White
DC 12V (50mA maximum)
GND
Blue/White
GND
D+
Purple/White
RS485 TX +
D-
Gray
RS485 TX -
DI
Green/White
Digital signal input
DO
Orange/White
Digital signal output (alarm)
User can refer to the schematic below to make a proper connection between I/O connector and
external sensor and output device.
Explanation of External I/O Circuit Diagram:
CAUTION
THE LOW VOLTAGE/CURRENT CIRCUITS AND HIGH VOLTAGE/ CURRENT CIRCUITS
ARE IN THE NETWORK CAMERA CIRCUIT. THE QUALIFIED ELECTRICIAN SHOULD DO
THE WIRING NOT BY YOU. INCORRECT WIRING COULD DAMAGE NWTWORK