Specification – AVer Data BOX User Manual
Page 8
8
7.
In the POS Mapping dialog box, click OK to accept the settings and Cancel to exit without saving
the new setting. Click
or right-click screen to call out the virtual keyboard to enter the value.
For uppercase, click Caps button. To exit, click Esc.
(1) Name: Enter a name to identify the POS.
(2) Protocol: To select the protocol, click Setting button (see Setup POS Protocol)
(3) Skip first: Set the number of lines you want to be removed
(4) Front Color: Select the POS text color.
(5) Port Setting: Select the Local or Remote port to where it is connected.
Local - select the COM port number which is connected.
Baud Rate
– Select the baud rate of the connection port.
(6) Map to Channel: Select to which camera number to display the transaction text.
(7) Text Filter: Enter the word you want to be removed.
Specification
Input
RS-232 port from POS
Parallel port from POS
Output
RS-232 port to printer
Parallel port to printer
RS-232 port to DVR
RS-485(9600bps~19200bps)
Baud-rate setting
9600, 19200, 57600, 115200 bps
DC IN
DC 5V, 2A
Dimensions
172(W) × 30(H) × 108(D) mm
© 2011 AVer Information Inc. All rights reserved.