3 power supply connection – Arc Machines 217 WDR User Manual
Page 16
![background image](/manuals/634140/16/background.png)
M O D E L 2 1 7 W D R
O P E R A T O R ’ S M A N U A L
12
3.3 POWER SUPPLY CONNECTION
1. Below is a view of the input and output sides of the Model 217 WDR Power Supply with
all connectors visible. Connect the A.C. power cord into a utility power source ranging
from 115/230 volts, 50/60 hertz single phase.
2. Connect Argon (or mixed gas) from an external source to the Model 217 WDR ARC
GAS INPUT connector (I.D. Purge Gas optional), the ARC GAS is monitored by the
computer and MUST be run through the power supply to avoid a FAULT. Connect
the weld head electrode, ground, motor control, and gas line via the 24 inch cheaters or
15 foot adapter cable to the power supply.
The Model 217 WDR is intended for typical GTAW gases ONLY.
NEVER CONNECT
OXYGEN OR ACETYLENE
to the Model 217 WDR or weld head.
NOTE:
It is recommended to connect the Model 217 WDR to a dedicated A.C. circuit.
Power Input: 115/230 VAC, 50/60 hertz
Purge Input: 5 to 50 psi or 34 to 344 kPa.
CB-1
Input A.C.
Arc Gas/ ID Purge Gas
Inputs
/Outputs
AMI/EXEL by AMI
Weld Head Connections
ID Purge-Manual ON/OFF
Remote Pendant
SWAGELOK Weld Heads
Ethernet port
USB ports