1positionning on the threshold k-ns91z, 1a 8 – Alumax K-NS93Z User Manual
Page 8
1
POSITIONNING ON THE THRESHOLD
K-NS91Z
INSTALLATION MANUAL
Use a measuring tape to mark the center of the
threshold of the base.
Using 1 3/8” screws (2), fasten the expander to
the bottom track by placing the bottom connec-
tor between the bottom track and expander.
Place glass clips (2) on the bottom edge of the
panel and slide it into the expander
and
bottom track.
Place glass clips (2) on the top edge of the
panel. Fasten the top track using 1 3/8” screws
(2) by placing the top connector between the
top track and expander.
Insert the vertical column onto the
panel
and screw into the top and bottom track using
the 3/4” screws (2).
Screw the magnetic expander to the top and
bottom tracks using the 1 3/8” screws (4) by
placing the two connectors in between.
1a.
1b.
1c.
1d.
1e.
1f.
1a
8
Opening
See table
INTERIOR
SHOWER SIDE
Model
Opening adjustment (min / max)
K-NS91Z-48
min: 46” / max: 47 1/4”
K-NS91Z-60
min: 58” / max: 59 1/4”
K-NS91Z-72
min: 70” / max: 71 1/4”
* Tolerance on dimensions ± 1/8” (3mm)
8