background image

Page 5 of 7

EPH-N00-06095

5-19-04

4

5

Slide the strike jamb [G] over one of the mounted wall

jambs [C] with the magnet facing outward.
Measure the wall-to-wall opening at the top and at the
bottom of the wall jambs and note the smaller dimension.
Measure the entire width of the door panel [B] from the
outside edge of the side rail to the edge of the glass on the
strike side. Add 2 1/4" to the door width, subtract the total
from the minimum wall-to-wall opening and divide the result
by two. This should be the distance from the wall to the
strike jamb at the closest point. Plumb the strike jamb
vertically and mark its location on the wall jamb with a
pencil.

Inside the shower enclosure, drill two 1/8" holes
thru the strike jamb [G] and into the wall jamb [C] 3/8" to
3/4" from the wall and approximately 1" vertically from each
end of the strike jamb. Drill a third hole centered between
the first two, then enlarge the three outer holes with a 3/16"
drill for clearance on the self-tapping screws. Attach the
strike jamb permanently with three #6 x 3/8" pan head
screws [F].

EXTERIOR

6

Slide the hinge jamb of the door panel assembly [B]

over the mounted wall jamb [C] so the door will open
outward.
Adjust the door panel assembly so there is 1/4" clearance
between the strike jamb and the strike edge of the glass
door panel in the closed position. Mark the location
of the hinge jamb on the wall jamb with a pencil.

1/4”