TO ADJUST CHOKE CONTROL
The choke control has been preset at the
factory and adjustment should not be

necessary, check adjustment as de­
scribed below before loosening cable. If
adjustment is necessary, proceed as
follows:

1. With engine not running, move choke

control (located on dash panel) to full
choke position.

Remove air cleaner cover, filter and

cartridge plate to expose carburetor
choke (See “AIR FILTER" in the

Maintenance section of this manual).
Choke should be closed. If it is not,
loosen casing clamp screw and move
choke cable until choke is completely
closed. Tighten casing clamp screw
securely.

Reassemble air cleaner.

2

.

3.

4.

Closed for Full
Choke

TO ADJUST CARBURETOR
The carburetor has been present at the
factory and adjustment should not be

necessary. However, minor adjustment
may be required to compensate for

differences in fuel, temperature, altitude

or load. If the carburetor does need
adjustment, proceed as follows:
In general, turning the adjusting needles
in (clockwise) decreases the supply of

fuel to the engine giving a leaner fuel/air

mixture. Turning the adjusting needles out
(counterclockwise) increases the supply
of fuel to the engine giving a richer fuel/
air mixture.
IMPORTANT: Damage to the needles
and the seats in carburetor may result if
screw is turned in too tight.

PRELIMINARY SETTING -
1. Be sure you have a clean air filter, and

the throttle control cable is adjusted
properly (see “TO ADJUST
THROTTLE CONTROL CABLE” in the
Service and Adjustments section of
this manual).

2. With engine off turn idle fuel adjusting

needle in (clockwise) closing it finger
tight and then turn out (counterclock­
wise) 1 turn.

FINAL SETTING-

1. Start engine and allow to warm for five

minutes. Make final adjustments with

engine running and shift/motion
control lever in neutral (N) position.

NOTE: The high idle is set at the fectory

and cannot be adjusted.
2. Idle speed setting - With throttle

control lever in slow position, engine
should idle at 1200 RPM. If engine
idles too slow or fast, turn idle speed
adjusting screw in or out until correct
idle is attained.

3. Idle fuel needle setting - With throttle

control lever in stow position, turn idle
fuel adjusting needle in (clockwise)

until engine speed decreases and

then turn out (counterclockwise)

approximately 3/4 turn to obtain the
best low speed performance.

4. Recheck idle speed. Readjust if

necessary.

ACCELERATION TEST -

5. Move throttle control lever from slow to

fast position. If engine hesitates or
dies, turn idle fuel adjusting needle
out (counterclockwise) 1/8 turn.

Repeat test and continue to adjust, if
necessary, until engine accelerates

smoothly.

High speed stop is factory adjusted. Do

not adjust-damage may result.

IMPORTANT: Never tamper with the

engine governor, which is factory set for

proper engine speed. Overspeeding the

engine above the factory high speed
setting can be dangerous. If you think the
engine-governed high speed needs

adjusting, contact Sears or other qualified
service center, which has proper equip­
ment and experience to make any
necessary adjustments.