Troubleshooting guide – Craftsman 921.153101 User Manual
Page 9
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Troubleshooting Guide
The air compressor should be turned off and unplugged from the power source before any
maintenance is performed as well es Che air bled from the tartk and the unit allowed time to cool
Personal injuries could occur from moving parts, olectrical sources, compressed air, or hot surfaces
A
WARNING
PROBLEM
POSSIBLE CORRECTION
Air leaks at the check valve
or at the pressure relief valve.
A defective check valve results in a constant air leak at the pressure relief valve
when there is pressure in the tank and the compressor is shut off. Drain the tank,
then remove and clean or replace the check valve
Air leaks between head and
cylinder.
Be sure of proper torque on head bolts. If leak remains, contact a service technician.
Air leak from safety valve.
Operate the safety valve manually by pulling on the ring, If the valve continues to
leak when in the closed position, it should be replaced.
Pressure reeding on the
regulated pressure gauge
drops Mdien an accessory is
used.
If there IS an excessive amount of pressure drop when the accessory is used,
replace the regulator.
NOTE:
Adjust the regulated pressure under flow conditions (while accessory is being used).
It is normal for the gauge to show minimal pressure loss during inidal use of №e
tool.
Excessive tank pressure.
Move the Auto-On/Off lever to the Off position, if the unit doesn't shut off, unplug it
from the power source and contact a service technician.
Motor will not start.
Make sure power cord is plugged in and the switch is on. Inspect for the proper size
fuse in your circuit box. If the fuse was tnpped, reset it and restart the unit, if
repeated tripping occurs, replace the check valve or contact a service technician.
Excessive moisture In the
discharge air.
Remove the water in the tank by draining after each use. High humidity
environments wii cause excessive condensation utilize water flltsra on your air
line.
NOTE:
Water condensation is not caused by compressor malfunction. Be sure the
compressor's iiir output is greater than your tool's air consumption rate.
Air leaks from the tank body
or tank welds
Never drill into, weld or otherwise modify the air tank or it will weaken. The tank can
rupture or explode Compressor cannot be repaired, Discontinue use of the air
compressor.