STORAGE
J
AFTER EACH USE
Water should not remain in the unit for long periods of
time. Sediments or minerals can deposit on pump
parts and “freeze” pump action. Follow these
procedures after every use:
1
.
Flush detergent siphoning tube by placing the filter
into a pail of clean water while running pressure
washer in low pressure mode. Flush for one to two
minutes.
Shut off engine, let it cool, then remove ail hoses.
Disconnect spark plug wire from spark plug.
Empty pump of all liquids by pulling recoil handle
about 6 times. This should remove most liquid in
pump.
If storing for more than 30 days see “Long Term
Storage” on next page.
Coil high pressure hose and inspect it for damage.
Cuts in hose or fraying could result in leaks and
loss of pressure. Should any damage be found,
replace hose. DO NOT attempt to repair a
damaged hose. Replace hose with genuine Sears
7. Disconnect hose from spray gun and high
pressure outlet on pump. Drain water from hose,
gun, and nozzle extension. Use a rag to wipe off
hose.
8. Reconnect spark plug wire to spark plug.
9. Store unit in a clean, dry area.
^ WARNING
WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN
TANK
• Store
away from furnaces,
stoves, water heaters,
clothes
dryers or other appliances that have pilot
light
or other
ignition source
because
they can ignite fuel vapors.
WHEN DRAINING FUEL
• Turn pressure washer OFF and let it cool at
least
2
minutes
before
removing fuel cap. Loosen cap slowly to
relieve pressure in tank.
• Drain
fuel tank outdoors.
• Keep fuel away from sparks, open flames, pilot lights,
heat,
and other ignition sources.
• DO NOT light a
cigarette
or smoke.
WINTER STORAGE
CAUTION
You must protect your unit from freezing
J
Failure to do so will permanently
damage
your pump
and render your
unit Inoperable,
Freeze damage is not covered under warranty.
To protect the unit from freezing temperatures:
1. Flush detergent siphoning tube by placing filter
into a paii of dean water while running pressure
washer in low pressure mode. Flush for one to two
minutes.
2. Empty pump of all pumped liquids by pulling recoil
handle about 6 times. This should remove most
liquid in pump.
3. Use pump saver, available at Sears retail item
71-74403, to treat pump. This minimizes freeze
damage and lubricates pistons and seals.
4. If pump saver is not available, connect a 3-foot
section of garden hose to water inlet adapter.
Pour RV-antifreeze (antifreeze without alcohol)
into hose. Pull recoil handle twice. Disconnect
3-foot hose.
17