External Control Device Setup

Set ID

- Use this function to specify a monitor ID number.
- Refer to ‘Real Data Mapping

V .

See page 37.

1. Press the

MENU

button and then use

d

/ E

button to select the

SPECIAL

menu.

2. Press the

g

button and then use

d

/

E

button to select

Set ID.

3. Press the

g

button and then use

f

/

g

button to adjust

Set ID

to choose the

desired monitor ID number. The adjustment range of

Set ID

is 1 ~ 99.

4. Press the

ENTER

button to save.

oi

Communication Parameters

Baud rate :9600 bps (UART)
Data length : 8 bits
Parity : None

Use a crossed (reverse) cable.

Command Reference List

Stop bit: 1 bit
Communication code : ASCII code

Transmission / Receiving Protocol

Transmission

DATA

(Hexadecimal)

01. Power

k

a

0~ 1

02. Input Select

k

b

0~6

03. Aspect Ratio

k

C

0~3

04. Screen Mute

k

d

0~ 1

05. Volume Mute

k

e

0~ 1

06. Volume Control

k

f

0~64

07. Contrast

k

g

0~64

08. Brightness

k

h

0~64

09. Color

k

i

0~64

10. Tint

k

i

0~64

11. Sharpness

k

k

0~64

12. OSD Select

k

1

0~ 1

13. Remote Control Lock Mode

k

m

0~ 1

14. PIP/DW

k

n

0~3

15. Split Zoom

k

p

0~99

16. PIP Position

k

q

0~3

17. Treble

k

r

0~64

18. Bass

k

S

0~64

19. Balance

k

t

0~64

20. Color Temperature

k

u

0~3

21. Red Adjustment

k

V

0~3C

22. Green Adjustment

k

w

0~3C

23. Blue Adjustment

k

$

0~3C

24. PIP Input Source

k

y

0~6

25. Abnormal State

k

Z

0~a

26. ISM Method

i

p

0~3

27. Low Power

i

q

0~ 1

28. Orbiter Time Setting

j

r

1 ~FE

29. Orbiter Pixel Setting

j

S

1~9

30. Picture Size

j

t

0~14

31. Auto Config

j

u

1

[Command 1][Command2][ ][Set ID][ ][Data][Cr]

* [Command 1]: First command to control PDP set. (j, k or m)
* [Command 2]: Second command to control PDP set.
* [Set ID]: You can adjust the set ID to choose desired monitor

ID number in Special menu. Adjustment range is 1

~ 99. When selecting Set ID ‘O’, every connected

PDP set is controlled. Set ID is indicated as deci­

mal (1~99) on menu and as Hexa decimal
(0x0~0x63) on transmission/receiving protocol.

* [DATA]: To transmit command data.

Transmit ‘FF’ data to read status of command.

* [Cr]: Carriage Return

ASCII code ‘OxOD’

* [ ]: ASCII code ‘space (0x20)’

OK Acknowledgement

[Command2][ ][Set ID][ ][OK][Data][x]

* The Monitor transmits ACK (acknowledgement) based on

this format when receiving normal data. At this time, if the
data is data read mode, it indicates present status data. If
the data is data write mode, it returns the data of the PC
computer.

Error Acknowledgement

[Command2][ ][Set ID][ ][NG][Data][x]

* The Monitor transmits ACK (acknowledgement) based on

this format when receiving abnormal data from non-viable

functions or communication errors.

Data 1: lilegal Code

2: Not supported function

3: Wait more time

COM- COM-

DATAO

DATAI

DATA 2

DATA3

MAND 1 MAND 2

(Hexadecitnai) (Hexadecimal) (Hexadecsmai)(Hexadecitnai)

32. Tune Command m

01 ~7D

0

0

mainsub/TuneBand

33. Channel Add/Del m

b

0 ~ 1

34. Key

m

c

Key code

Owner’s Manual 37