THERMAL PROTECTION
This unit is Thermally Protected. If the cooling fan stalls or the unit is not field wired in accordance with the wiring
Diagrams (Fig. 3), the heat generated by the lamps will cause the protector to cut the unit off. After the unit has cooled off, the protector will
switch the unit back on, allowing the lamps to become energized. The unit will again heat up and cut off. This cycle will be repeated over and
over unless steps are taken to correct the problem. THIS CONDITION SHOULD NEVER BE ALLOWED TO CONTINUE. If necessary, the
unit should be serviced by an authorized representative.
In addition, the ventilator motor has an internal thermal protector in case the ventilator does not start when the ventilator switch is turned on.
This condition should be investigated. NEVER LEAVE SWITCH IN “ON” POSITION WHEN VENTILATOR DOES NOT START! Always
disconnect unit from power source before servicing it.

FIG. 4

FIG. 5

ROOF CAP

WALL CAP

4” DIA. DUCT

TYPICAL DUCTING

INSTALLATION

HORIZONTAL

AND HORIZONTAL

TO VERTICAL

DISCHARGE

SPRING
MOUNT

INSTALLATION IN EXISTING HOMES
1.

Carefully read all previous installation instructions and
follow those applicable to your installation, including
ducting and wiring. (See Figs. 3, 4, & 5)

2.

Drill a small hole in the ceiling from below in proposed
location, then locate this hole in the attic.

3.

In attic, mark ceiling for cutout by using housing as
template. Note: The housing can not be adjusted
closer than 4” to the side of either joist on 24” O.C.
construction.
Using this line make a cutout about
1/4” larger.

4.

Place housing with mounting brackets installed into
hole and rest mounting brackets on sheetrock. Adjust
housing so that it will be flush with the finished ceiling.
(See dimension “A” in Fig. 2). Extend and nail all four
ends of mounting brackets.

5.

Perform steps 2 through 6 as for new construction.

SPECIFICATIONS:

MODEL

VOLTS

MAXIMUM

BTHU

DUCT

CFM

H.V.I. CERTIFICATION (SQ. FT.)

WATTS

SIZE

RATING

BATH

KITCHEN

OTHER

A564

120

375

1280

N/A

N/A

N/A

N/A

N/A

B560

120

375

1280

4”

70

65

N/A

85

B660W

120

750

2560

4”

70

65

N/A

85

B674W

120

750

2560

N/A

N/A

N/A

N/A

N/A

LIMITED WARRANTY

Dear Customer,

Thank you for your interest in Marley Engineered Products. We’re sure you will enjoy its
benefits for many years to come. Please take a minute to fill out the following information
and keep it in your permanent records.

Date Purchased Date Installed

Model Number

Serial Number

LIMITED WARRANTY

This Marley Engineered Products heater is warranted to be free of defects in material and
workmanship for 12 months from date of original purchase.

There is no other warranty, express or implied, except such as is expressly set forth herein.
Seller will not be liable for any general, consequential, or incidental damages, including without
limitation any damages for loss of use or loss of profits, for any breach of warranty or for
negligence. Seller’s liability and buyer’s exclusive remedy are limited to the repair of defective
goods or the shipment of equivalent goods, or the granting of a reasonable allowance on
account of any defects, as the seller may elect.

To obtain performance under this warranty, you must:

1.

Contact the Marley Engineered Products Service Department at 1-800-642-HEAT
between the hours of 8:00 a.m. and 5:00 p.m. E.S.T. Monday through Friday.

2.

Provide the model number of the product, the date of installation, and state the nature of
the difficulty being experienced.

Products within warranty which have been installed and returned to the seller for repair will
be repaired and returned as used products. Repairs to products outside the warranty period
will be subject to labor and parts charges.

Some states have enacted legislation which (a) does not allow the inclusion of limitations
on incidental or consequential damages; (b) does not allow limitations on the length of a
warranty period; (c) precludes exclusion, during the period of a limited warranty, of any
implied warranties of merchantability or fitness for purpose.

To the extent of such provisions being applicable in your state, the limitations in this
warranty may not apply.

TO ENSURE SAFE OPERATION

• Be sure that this unit is correctly installed and wired by a qualified installer in accordance

with the instructions and applicable NEC or equivalent codes.

• Be sure that operating instructions are followed and that moving and heating parts are

kept clean and free from obstructions.

Any warranties granted or liabilities assumed hereunder will not apply to goods that have
been damaged in transit, altered, repaired, installed or operated otherwise than in
conformity with the above requirements for safe operation.

3.

The Marley Engineered Products Service Representative will determine the best way
to resolve the difficulty.

HOW TO ORDER REPAIR PARTS

In order to obtain any needed repair or replacement parts, warranty service or

technical information, please contact Marley Engineered Products Service Center
toll-free by calling 1-800-642-HEAT.

When ordering repair parts, always give the information listed as follows:

1. The Part Number
2. The Model Number
3. The Part Description
4. Date of Manufacture

Part No. 5200-2517-001

ECR 34491

9/01

470 Beauty Spot Rd. East
Bennettsville, SC 29512 USA

This manual is related to the following products: