beautypg.com

Caution ! fig. 3, Warning – Qmark B660W Infrared Heaters User Manual

Page 3

background image

2.

Remove outlet cover. Run 120VAC, 60Hz power cables from wall switch/switches to appropriate knockout in housing. Remove
knockout and install BX or Romex connector in outlet box. (Refer to Fig. 3 for the wiring diagram designated for the model being
installed.) Feed cables through the box connector and make connections in outlet box using approved connectors. Connect ground
wire to green ground screw.

CAUTION: Do not disconnect or separate any factory installed connections. Cooling fan must be on when lamp/lamps are on.

BE SURE ALL WIRING COMPLIES WITH LOCAL AND NATIONAL ELECTRICAL CODES

AND THE UNIT IS PROPERLY GROUNDED

a

CAUTION

!

FIG. 3

OUTLET BOX

LAMP

RED

BLACK

WHITE

WHITE

BLACK

WHITE

GROUND

WHITE

BLACK

THERMAL
PROTECTOR

GROUND
SCREW

WALL
SWITCH

120V 60 HZ

POWER SUPPLY

MODEL A564 WIRING DIAGRAM

COOLING FAN

(DO NOT

SEPARATE LEADS)

OUTLET BOX

LAMP

RED

BLACK

WHITE

WHITE

BLACK

WHITE

GROUND

WHITE

BLACK

THERMAL
PROTECTOR

GROUND
SCREW

VENTILATOR
AND LAMP
WALL SWITCH

120V 60 HZ

POWER SUPPLY

MODEL B560 WIRING DIAGRAM

(DO NOT

SEPARATE LEADS)

VENTILATOR MUST BE

ON WHEN LIGHT IS ON.

VENTILATOR

MOTOR

OUTLET BOX

FIRST LAMP

BLACK

BLACK

BLACK

WHITE

WHITE

BLACK

WHITE

GROUND

WHITE

BLACK

THERMAL
PRO-
TECTOR

GROUND

SCREW

120V 60 HZ

POWER SUPPLY

MODEL B660W WIRING DIAGRAM

VENTILATOR

MOTOR

SECOND LAMP

COOLING FAN

(DO NOT

SEPARATE LEADS)

RED

BLUE

WHITE

OUTLET BOX

FIRST LAMP

BLACK

BLACK

WHITE

WHITE

BLACK

WHITE

GROUND

WHITE

THERMAL
PROTECTOR

GROUND
SCREW

120V 60 HZ

POWER SUPPLY

MODEL B674W WIRING DIAGRAM

SECOND LAMP

COOLING FAN

(DO NOT

SEPARATE LEADS)

RED

BLUE

LAMPS

WALL

SWITCH

VENTIL-
ATOR
WALL
SWITCH

WALL
SWITCH

3

(Ventilator Models Only)
3.

Run four inch round duct from ventilator air discharge outlet to wall cap or roof cap. (See Fig. 4)

Important: Be sure nothing obstructs the discharge of the ventilator. Take precautions to insure that insulation does not get into duct
work or air discharge opening.
4.

Install grille by hooking one end of the two springs provided in the holes in either end of the housing. Hook the other ends of the
springs in the small holes in the grille. (See Fig. 5).

5.

Install R-40 reflector-type infrared heat lamp/lamps 375 watt maximum (not included).

6.

Insure the grille opening/openings are centered around the lamp/lamps. The lamps may not give satisfactory performance if in
contact with the grille.

RISK OF FIRE!

USE OF LAMPS OTHER THAN THOSE SPECIFIED CONSTITUTES A FIRE HAZARD

a

WARNING

!

RISK OF FIRE!

NEVER PLACE ANYTHING IN FRONT OF LAMPS OR BLOCK UNIT IN ANY MANNER.

a

WARNING

!

This manual is related to the following products: