ProTemp PT-150V-GFA User Manual
Page 4

NEVER LEAVE HEATER UNATTENDED WHILE BURNING,
CONNECTED TO A POWER SOURCE, OR WHILE
CONNECTED TO A FUEL SOURCE
© 2014, Pinnacle Products International, Inc.
Propane Forced Air Heater User’s Manual
®
ALWAYS use the electrical power (voltage and
frequency) specified on the model plate of the heater.
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.
ALWAYS install the heater so that it is not directly
exposed to water spray, rain, dripping water, or wind.
– Use heater in accordance with all local codes.
In the absence of local codes, refer to The
National Fuel Code, ANSI Z223.1.
–
This heater is shipped from the factory
for use with propane (LP) gas only. Do not
convert to any other gas. Installation must
conform to local codes, or in their absence,
with the standard for the Storage and
Handling of Liquefied Petroleum Gases ANSI/
NFPA 58 and the Natural Gas and Propane
Installation Code CSA B149.1.
– Gas supply connections should be checked
by using a 50/50 soap and water solution.
Never use a flame to check for gas leaks.
– Locate LP cylinder at least 6 feet (10 ft. in
Canada) from the heater, and do not direct
heater discharge towards the LP cylinder
unless it is at least 20 feet from the heater.
– Use only the regulator and hose assembly
provided with this heater. Inspect the
regulator/hose assembly prior to each use of
the heater. If there is excessive abrasion or
wear, or if the hose is cut, replace it with the
proper assembly shown in the parts list, prior
to using the heater.
Minimum and Maximum Inlet Pressure
PT-40
PT-60V PT-125V PT-150V
Min.
5 PSI
Max.
Bottle Pressure
Safety Information
The hose assembly shall be
pro tected from traffic, building
material and contact with hot surfaces both
during use and while in storage.
WARNING
1. Remove all packing items applied to heater for
shipment. Keep plastic cover caps attached to
inlet connector and hose / regulator assembly
for storage.
2. Remove all items from carton
3. Check all items for shipping damage. If the
heater is damaged, promptly inform dealer
where you purchased the heater.
The Propane (LP) gas
pressure regulator and hose
assembly supplied with the heater must be
used without alteration.
CAUTION
Unpacking
3
X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
RISK OF FIRE! DO NOT POSITION HEATER IN A DOWNWARD ANGLE.
ALWAYS LOCATE HEATER ON A STABLE AND LEVEL SURFACE!
WARNING
RISK OF ELECTRIC SHOCK!
Figure 1
For use with propane (LP)
gas only.
WARNING
Electrical Grounding
Instructions: This appliance
is equipped with a three-prong (grounding)
plug for your protection against shock
hazard and should be plugged directly into a
properly grounded three-prong receptacle.
WARNING
WARNING