beautypg.com

Culligan GoodWater Machine DrinkingWater System User Manual

Page 18

background image

Average

USEPA

Minimum

Average

Influent

SDWA

2

Reduction

Percent

Percent

Substance

Concentration

MCL (mg/L)

Requirement

Removal

Removal

Arsenic

2

0.03 +/- 10%

0.025

96.6%

98.0%

Barium

10.0+/- 10%

2.0

90.0%

90.0%

Cadmium

0.03 +/- 10%

0.005

90.0%

96.4%

Hexavalent Chromium

0.30 +/- 10%

0.1

86.7%

86.7%

86.6%

Trivalent Chromium

0.30 +/- 10%

0.1

85.7%

85.7%

Copper

3.00 +/- 10%

1.3

96.5%

99.2%

Cysts

6

>50,000/ml

99.95%

99.99%

99.99%

Fluoride

8.0 +/- 10%

1.5

89.8%

95.2%

Lead

0.15 +/- 10%

0.010

97.0%

98.1%

Nitrate plus Nitrite (both as N)

30.0 +\- 10%

10.0

Nitrate

3

27.0 +/- 10%

10.0

74.03%

80.4%

Nitrite

3.0 +/- 10%

1.0

68.3%

75.8%

Radium 226/228

4

25pCi/L +/- 10%

5pCi/L

80.0%

80.0%

Selenium

0.10 +-/10%

0.05

93.02%

96.8%

Product

TDS Reduction

System Daily Prod. Rate

Average Maximum

Average

Prod. Rate w/o Storage

USEPA

Inffluent

Effluent

Minimum

Effluent

Average

Tank

to Pressurized

Tank to

SDWA

Conc.

Conc.

Percent

Conc.

Percent

Size

Storage Tank

Atmosphere

MCL (mg/L)

(mg/L)

(mg/L)

Removal

(mg/L)

Removal

2 gallon 12.8 gpd (48.45L)

30 gpd

187

776

160

79%

112

85.5%

3 gallon 12.1 gpd (45.8L)

30 gpd

187

770

100

87%

70

90.9%

9 gallon 11.7 gpd (44.2L)

30 gpd

187

758

82

89%

65

91.4%

* This is a factory specification for membrane production. Actual production rate and TDS rejection will depend on
temperature, water pressure, TDS level, membrane variation and usage pattern.

TESTING CONDITIONS (Complete Systems)
Temperature:
77°F ± 2°F

pH: 7.5 ± 0.5

Pressure: 50 psi

Turbidity: < 1 NTU

This system has been tested and shown to operate at its calculated recovery rating under standard test
conditions.

DIMENSIONS
Filter Assembly

7.5” W x 3” D x 16.5” H (20 cm W x 8 cm D x 42 cm H)

Storage Tank

- Standard

9” Diameter x 15” H (23 cm Diameter x 38 cm H)

- Medium

11” Diameter x 15” H (28 cm Diameter x 38 cm H)

- Large

15.5” Diameter x 22” H (40 cm Diameter x 56 cm H)

The Good Water Machine models listed above have been tested according to ANSI/NSF Standard 58 for effective
reduction of TDS, arsenic, barium, cadmium, hexavalent and trivalent chromium, copper, cysts, fluoride, lead, radium
226/228 and selenium as verified and substantiated by test data. The concentration of the indicated substances in water
entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the
system as specified in ANSI/NSF 58.

16

1. While testing was performed under standard laboratory conditions, actual performance may vary depending on water pressures, temperatures, and
other substances, which may be found in your water.
2. This system shall only be used for arsenic reduction on chlorinated water supplies containing detectable residual free chlorine.
3. Nitrate units are not certified for nitrate/nitrite reduction in water supplies with a pressure less than 4 psi (280 kPa). A booster pump is strongly
recommended.
4. Based upon testing methods using Barium as a surrogate. All concentrations in pCi.l: pico cutirs/L.
5. United States Environmental Protection Agency (USEPA) Safe Drinking Water Act.
6. Includes Giardia, Lamblia, Entamoeba Histolyca and Cryptosporidium.

SUBSTANCE REMOVAL

1

OUTPUT (Total Dissolved Solids (TDS) Reduction and Output Production