beautypg.com

Servicing your system (cont’d) – Culligan GoodWater Machine DrinkingWater System User Manual

Page 14

background image

12

6. In this step, you will need to observe water flowing to the drain. If the drain flow is

not visible with the current tubing connections, install a temporary drain tube in the
waste port of the manifold.
Turn on the supply valve. When water is seen flowing to
the drain, carefully loosen the capillary tube assembly retaining screws until the
flow to the drain increases.

NOTICE: When the assembly is about 3/16” out of the manifold, the o-ring seal for the
capillary tube is bypassed, but there should be no external leaks.
7. Rinse the manifold assembly for five minutes or until no chlorine is detected in

the water passing to the drain. Tighten the capillary assembly retaining screws.

8. Check the performance of the system according to the procedure outlined in the

“Performance and Technical Information” section of this manual. Replace the RO
membrane if necessary.

9. Instruct the customer to discard the first glassful of water from the system to flush

out any residual chlorine that might remain in the polishing filter tubing and
faucet. The polishing filter will remove any chlorine remaining in the storage
tank.

10.Record your service on the chart at the end of the Owner’s Guide.

Servicing Your System (cont’d)