Cleveland Range SteamChef 22CGT6 User Manual
Page 27

20
9) While the reservoir is filling with water, pour 1 to 1 ½ quarts (about a third of a 1-gallon bottle) of
DISSOLVE
®
descaler solution into the water reservoir.
• While
adding
DISSOLVE
®
descaler to the reservoir, pour it in slowly to avoid splashing the
liquid or overflowing the reservoir.
10) After automatic fill ends, turn OFF the Main External Power Switch. See Figure 3-1.
11) Leave the door open and let the DISSOLVE® work for 1 hour.
12) At the end of 1 hour, set the ON/OFF lever to the OFF position.
13) Turn the power ON at the Main External Power Switch.
14) After the 3-minute drain cycle completes, turn the ON/OFF lever back ON. (NOTE: If the reservoir
does not fill, dry off the water probe assembly).
15) After filling stops, add 1/2 gallon of water to the reservoir. Do not overflow the reservoir.
16) Turn the ON/OFF lever OFF to start the drain cycle.
17) After the reservoir drains, set the ON/OFF lever to the ON position to refill the reservoir.
18) Close the cooking compartment door and set the timer for 20 minutes (ON/OFF Control Models:
set the control to ON.). The steamer heats to normal operating temperature.
19) After 20 minutes turn OFF ON/OFF controls and turn the ON/OFF lever to OFF.
20) The 3-minute drain cycle starts.
• This is the final rinse of the reservoir.
21) If the reservoir drains slowly even after being descaled, turn OFF the steamer and clean the
drains with a NSF approved drain cleaner.
22) Once the scale is removed and the drain flows freely, the steamer is ready for normal operation.
B. Operator’s Troubleshooting Guide
The Troubleshooting Guide is a list of symptoms of problems that may be encountered during operation.
• “Problem” (left column) lists common operating problems.
• “Possible Cause” (center column) lists causes of problems in order they should be checked.
• “Remedy / Reference” (right column) lists fixes for problems from easiest to hardest.
• “Notes” in “Remedy / Reference column are at end of Table 3-1 Troubleshooting Guide.
ATTEMPTING TO REPAIR OR CORRECT PROBLEMS REQUIRING AN AUTHORIZED SERVICE
REPRESENTATIVE VOIDS WARRANTY
Table 3-1 Troubleshooting Guide
PROBLEM POSSIBLE
CAUSE REMEDY/REFERENCE
Power turned OFF at main external
power switch.
Turn ON power at main external power
switch.
ON/OFF lever not fully turned to the
ON position.
Turn lever to the ON position.
Power indicator light
does not turn ON when
ON/OFF lever is in the
ON position.
Inoperative controls or indicators.
See Note 1
Water supply to SteamChef shut OFF
Open water supply lines.
Water line strainer and/or external filter
system clogged.
Clean water supply strainer and/or
filter system. See Yearly Maintenance
in Chapter 7
Gas Supply is turned OFF.
Turn gas supply ON.
Water sensor is grounded by detergent
film, or scale.
Rinse water sensor assembly
thoroughly with vinegar solution, as
described in Chapter 6, Shutdown and
Cleaning Procedure.
Power ON and
SteamChef does not fill
Inoperative controls or solenoids.
See Notes 1 and 5
(Continued on Next Page)