beautypg.com

Dell PowerVault NX3100 User Manual

Page 37

background image

About Your System

37

Unused memory

detected. DIMM’s

installed in the

following slot

are not available

when in 128-bit

advanced ECC

mode: x,x,x.

The memory configuration is

not optimal for Advanced

ECC Memory Mode.

Modules in the specified

slots are unused.

Reconfigure the memory for

Advanced ECC Memory

Mode, or change the

memory mode to Optimized

or Sparing in the BIOS setup

screen. See "System

Memory" on page 82.

Warning: A fatal

error has caused

system reset!

Please check the

system event log!

A fatal system error

occurred and caused the

system to reboot.

Check the SEL for

information that was logged

during the error. See the

applicable troubleshooting

section in "Troubleshooting

Your System" on page 129 for

any faulty components

specified in the SEL.

Warning: Control

Panel is not

installed.

The control panel is not

installed or has a faulty cable

connection.

Install the control panel, or

check the cable connections

between the display module,

the control panel board,

and the system board.

See "Integrated Storage

Controller Card" on page 97.

Warning! No micro

code update

loaded for

processor n.

Micro code update failed.

Update the BIOS firmware.

See "Getting Help" on

page 157.

Message

Causes

Corrective Actions