Microprocessor Cooling Fan

Dell™ OptiPlex™ GX400 Service Manual 

  

Removing the Microprocessor Cooling Fan

  

Replacing the Microprocessor Cooling Fan

Removing the Microprocessor Cooling Fan

1.  Turn off the computer and devices, disconnect them from their electrical outlets, wait at least 5 seconds, and then

remove the computer cover

.

2.  

Rotate the power supply

away from the system board.

3.  

Remove the airflow shroud

.

4.  Disconnect the fan power cable from its connector on the system board (FAN). To locate this connector, see "

System Board Components

."

5.  Gently pull the plastic locking tab back, and slide the fan toward the system board.

Removing the Microprocessor Cooling Fan

 

6.  Lift the fan out of the chassis.

Replacing the Microprocessor Cooling Fan

To replace the microprocessor cooling fan, perform the

removal procedure

in reverse.