Dell OptiPlex 3010 (Mid 2012) User Manual
Page 61

Controls and Lights
NOTE: You can test the health of the power
system by pressing the test button. When
the system power supply voltage is within
specification, the self-test LED lights up. If
the LED does not light up, the power supply
may be defective. AC power must be
connected during this test.
Power
Wattage
Maximum Heat
Dissipation
Voltage
Mini-Tower
265 W
1390 BTU/hr
100 VAC to 240 VAC, 50 Hz to 60 Hz, 5.0 A
Desktop
250 W
1312 BTU/hr
100 VAC to 240 VAC, 50 Hz to 60 Hz, 4.4 A
Small Form Factor
240 W
1259 BTU/hr
100 VAC to 240 VAC, 50 Hz to 60 Hz, 3.6 A;
Coin-cell battery
3 V CR2032 lithium coin cell
NOTE: Heat dissipation is calculated by using the power supply wattage rating.
Physical
Height
Width
Depth
Weight
Mini-Tower
36.00 cm (14.17
inches)
17.50 cm (6.89 inches) 41.70 cm (16.42
inches)
8.87 kg (19.55 lb)
Desktop
36.00 cm (14.17
inches)
10.20 cm (4.01 inches) 41.00 cm (16.14
inches)
7.56 kg (16.67 lb)
Small Form Factor
29.00 cm (11.42
inches)
9.26 cm (3.65 inches)
31.20 cm (12.28
inches)
5.70 kg (12.57 lb)
Environmental
Temperature range:
Operating
10 °C to 35 °C (50 °F to 95 °F)
Storage
–40 °C to 65 °C (–40 °F to 149 °F)
Relative humidity (maximum):
Operating
20% to 80% (non-condensing)
Storage
5% to 95% (non-condensing)
Maximum vibration:
Operating
0.26 GRMS
Storage
2.2 GRMS
Maximum shock:
Operating
40 G
Storage
105 G
61