Environmental
NOTE: Outside the standard operating temperature
(10 °C to 35 °C), the system can operate down to 5 °C
or up to 40 °C for a maximum of 10% of its annual
operating hours.
For temperatures between 35 °C and 40 °C, de-rate
maximum allowable dry bulb temperature by 1 °C per 175
m above 950 m (1 °F per 319 ft).
< 1% of annual operating hours
–5 °C to 45 °C at 5% to 90% RH with 26 °C dew point.
NOTE: Outside the standard operating temperature
(10 °C to 35 °C), the system can operate down to –5
°C or up to 45 °C for a maximum of 1% of its annual
operating hours.
For temperatures between 40 °C and 45 °C, de-rate
maximum allowable dry bulb temperature by 1 °C per 125
m above 950 m (1 °F per 228 ft).
Expanded Operating Temperature Restrictions
•
Do not perform a cold startup below 5 °C.
•
The operating temperature specified is for a
maximum altitude of 3050 m (10,000 ft).
•
PCIe SSD is not supported.
•
GPU is not supported.
•
130 W (4 core) processor is not supported.
•
Redundant power supplies are required.
•
Non Dell qualified peripheral cards and/or
peripheral cards greater than 25 W are not
supported.
NOTE: The following additional restrictions apply to
DL2300.
•
Maximum 95 W processor supported on 3.5 inch
hard drive chassis.
•
Only SSDs are allowed in the hard drive slots at
the back of the 3.5 inch hard drive chassis.
Storage Temperature
–40 °C to 65 °C (–40 °F to 149 °F) with a maximum
temperature gradation of 20 °C per hour.