Appendix 3 : upsprop.xml file, 11 | p a g e – Dell UPS 1000R User Manual
Page 13
11 |
P a g e
N M C D e l l M 2 M p r o t o c o l ( X M L ) – 1 . 1
7. Appendix 3 : upsprop.xml file
-
<
SUMMARY Version
="
2.0
"
xmlns
="">
<
OBJECT name
="
UPS.PowerSummary.iProduct
">
UPS LI
OBJECT
>
<
OBJECT name
="
UPS.PowerSummary.iModel
">
T 1920
OBJECT
>
<
OBJECT name
="
UPS.PowerSummary.iSerialNumber
">
11-111111-11111-111-1111-111
OBJECT
>
<
OBJECT name
="
UPS.PowerSummary.iVersion
">
00.01.0019
OBJECT
>
<
OBJECT name
="
UPS.PowerSummary.RunTimeToEmpty
">
22050
OBJECT
>
<
OBJECT name
="
UPS.PowerSummary.RemainingCapacity
">
95
OBJECT
>
<
OBJECT name
="
UPS.PowerSummary.RemainingCapacityLimit
">
30
OBJECT
>
<
OBJECT name
="
UPS.PowerSummary.PercentLoad
">
0
OBJECT
>
<
OBJECT name
="
UPS.PowerSummary.PresentStatus.CommunicationLost
">
0
OBJECT
>
<
OBJECT name
="
UPS.PowerSummary.PresentStatus.NeedReplacement
">
0
OBJECT
>
<
OBJECT name
="
UPS.PowerSummary.PresentStatus.Discharging
">
0
OBJECT
>
<
OBJECT name
="
UPS.PowerSummary.PresentStatus.ACPresent
">
1
OBJECT
>
<
OBJECT name
="
UPS.PowerSummary.PresentStatus.Overload
">
0
OBJECT
>
<
OBJECT name
="
UPS.PowerSummary.PresentStatus.Good
">
1
OBJECT
>
<
OBJECT name
="
UPS.PowerSummary.PresentStatus.BelowRemainingCapacityLimit
">
0
OBJECT
>
<
OBJECT name
="
UPS.PowerSummary.PresentStatus.InternalFailure
">
0
OBJECT
>
<
OBJECT name
="
UPS.PowerSummary.PresentStatus.ShutdownImminent
">
0
OBJECT
>
<
OBJECT name
="
UPS.PowerSummary.DelayBeforeShutdown
">
-1
OBJECT
>
<
OBJECT name
="
UPS.PowerSummary.DelayBeforeStartup
">
-1
OBJECT
>
<
OBJECT name
="
UPS.Flow[4].ConfigApparentPower
">
1920
OBJECT
>
<
OBJECT name
="
UPS.PowerConverter.Input[2].PresentStatus.Used
">
0
OBJECT
>
<
OBJECT name
="
UPS.PowerConverter.Input[4].PresentStatus.Used
">
0
OBJECT
>
<
OBJECT name
="
UPS.OutletSystem.Outlet[1].iName
">
@@ UPS
OBJECT
>
<
OBJECT name
="
UPS.OutletSystem.Outlet[1].PresentStatus.Switchable
">
0
OBJECT
>
<
OBJECT name
="
System.ShutdownDuration
">
120
OBJECT
>
<
OBJECT name
="
System.RunTimeToShutdown
">
2147483647
OBJECT
>
<
OBJECT name
="
System.Outlet[2].RunTimeToShutdown
">
2147483647
OBJECT
>
<
OBJECT name
="
System.Outlet[3].RunTimeToShutdown
">
2147483647
OBJECT
>
<
OBJECT name
="
UPS.OutletSystem.Outlet[2].iName
">
@@ LS1
OBJECT
>
<
OBJECT name
="
UPS.OutletSystem.Outlet[2].DelayBeforeShutdown
">
-1
OBJECT
>
<
OBJECT name
="
UPS.OutletSystem.Outlet[2].PresentStatus.Switchable
">
1
OBJECT
>
<
OBJECT name
="
UPS.OutletSystem.Outlet[2].PresentStatus.SwitchOnOff
">
1
OBJECT
>
<
OBJECT name
="
UPS.OutletSystem.Outlet[2].RemainingCapacityLimit
">
0
OBJECT
>
<
OBJECT name
="
UPS.OutletSystem.Outlet[2].ShutdownTimer
">
2147483647
OBJECT
>
<
OBJECT name
="
System.Outlet[2].ShutdownDuration
">
120
OBJECT
>
<
OBJECT name
="
UPS.OutletSystem.Outlet[3].iName
">
@@ LS2
OBJECT
>
<
OBJECT name
="
UPS.OutletSystem.Outlet[3].DelayBeforeShutdown
">
-1
OBJECT
>
<
OBJECT name
="
UPS.OutletSystem.Outlet[3].PresentStatus.Switchable
">
1
OBJECT
>
<
OBJECT name
="
UPS.OutletSystem.Outlet[3].PresentStatus.SwitchOnOff
">
1
OBJECT
>
<
OBJECT name
="
UPS.OutletSystem.Outlet[3].RemainingCapacityLimit
">
0
OBJECT
>
<
OBJECT name
="
UPS.OutletSystem.Outlet[3].ShutdownTimer
">
2147483647
OBJECT
>
<
OBJECT name
="
System.Outlet[3].ShutdownDuration
">
120
OBJECT
>
<
OBJECT name
="
System.Description
">
Dell UPS Tower 1920W
OBJECT
>
<
OBJECT name
="
System.Bitmap
">
Dell2700R.jpg
OBJECT
>
<
OBJECT name
="
System.Location
">
Room DELL
OBJECT
>
<
OBJECT name
="
System.Contact
">
Pierre
OBJECT
>
<
OBJECT name
="
System.LastAcquisition
">
2009/05/15 11:24:40
OBJECT
>
SUMMARY
>