Figure 6. pri register – CH Tech Pulse Generator User Manual
Page 17

11
3.5.2 Pulse Configuration Registers
Pulse Repetition Interval Register (08) This read/write register controls the pulse repetition
interval and the state of the output relay. See Figure 6 for details.
08
PRI Register
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Write
OEN
Range
Not Used
PRI Multiplier
Read
OEN
Range
Not Used
PRI Multiplier
OEN
Output Relay Enable (1 = enabled/output on)
Range
PRI & Delay Range
bit 14 13 12
0 0 0 25 ns
0 0 1 100 ns
0 1 0 1
s
0 1 1 10
s
1 0 0 100
s
1 0 1 1 ms
1 1 X invalid
PRI Multiplier
PRI Multiplier (period = PRI Multiplier
Range)
NOTES:
1) The Range field is used for both the PRI and Delay time settings.
2) The minimum programmable period is 100 nsec. Therefore the minimum PRI
Multiplier is 4 in the 25 nsec range, and 2 for all other ranges.
3) The maximum PRI Multiplier is 1023; therefore, the maximum programmable period
is 1.023 sec.
4) For highest accuracy use the smallest range with a larger multiplier.
Figure 6. PRI Register