beautypg.com

Example cmdlines.txt, Ppendix, Xample – Dell PowerEdge 2970 User Manual

Page 18: Nswer, Sing a, Icrosoft, Isual, Asic, Cript in, Etup

background image

Dell Enterprise Server Windows Installation Best Practices with Broadcom NetXtreme Devices

[TcpipParams.Adapter2]
SpecificTo=Adapter2
IPAddress=192.168.2.125
SubnetMask=255.255.255.0
DHCP=no
DefaultGateway=192.168.2.132
WINS=yes
winsServerList=192.168.2.2
DNSServerSearchOrder=192.168.2.120

[TcpipParams.Adapter3]
SpecificTo=Adapter3
IPAddress=192.168.3.125
SubnetMask=255.255.255.0
DHCP=no
DefaultGateway=192.168.2.132
WINS=yes
winsServerList=192.168.2.2
DNSServerSearchOrder=192.168.2.120

[MassStorageDrivers]
"DELL PERC5 RAID Controller Driver (Server 2003 32-bit)"=OEM

Example cmdlines.txt

The cmdlines.txt file must be placed in the $OEM$ directory of the distribution share and
the unattended answer file must have the “OemPreinstall = Yes” line under the
[Unattended] section.

[Commands]
“C:\Netset c:\unattend.txt”

9.3.

Appendix C – Example Answer File Using a Microsoft Visual Basic
Script in SetupParams to Install the Broadcom Drivers Via the
Installer, Install SNP, and Use netset.exe to Apply Network Settings,
With Example VB Script


[UserData]
FullName="DellServer"
OrgName="Dell"
ComputerName="PEServer"
ProductID=" Removed, Product ID goes here "
Keyboard="en"

[Unattended]
DriverSigningPolicy=Ignore
NtUpgrade=no
OverwriteOemFilesOnUpgrade=no
FileSystem=ConvertNTFS
OemPreinstall=yes
ConfirmHardware=yes

Page 18