Figure 10: replacing the outer power supply – Dell POWEREDGE R515 User Manual
Page 11
Cable Routing Procedures for Dell™ PowerEdge™ R515 Systems
Page 9
Figure 10: Replacing the Outer Power Supply
Section 4: Cabling a PowerEdge™ R515 System Installed in Static Rails
NOTE: The CMA is compatible with the sliding rails only, not the static rails.
1. Follow the instructions contained in the
Rack Installation Instructions
found in the static rail kit
to install the server into a two-post or four-post rack.
2. Install the hook and loop straps provided in the rail kit through the slots in the rear brackets of
the rails as described in the
Rack Installation Instructions
.
3. Connect all applicable cables to the rear of the system and verify that all connections are
secure.
4. Using the hook and loop straps, bundle the cables and secure them to either the left rail or
right rail as described in the
Rack Installation Instructions
. See Figure 11 for an example of data
cables that are secured to the left rail and power cables that are secured to the right rail (as
viewed from the rear of the system).
Figure 11: Cabling a System Installed in Static Rails
Disconnected inner
CMA bracket