beautypg.com

Crestron electronic AV2 User Manual

Page 12

background image

2-Series Integrated Dual Bus Control System

Crestron AV2 & PRO2

Connectors, Controls & Indicators (Continued)

#

CONNECTORS

1

,

CONTROLS & INDICATORS

DESCRIPTION

14

COM (A – F)

5, 6, 7

COM F

COM A

(6) DB9 male, bidirectional RS-232/422/485 ports. Up to 115.2k
baud, hardware and software handshaking support. Ports C-F
support C2N-NPA8 Network Poll Accelerator

8

.

PIN DIRECTION

DESCRIPTION

1*

To AV2 or PRO2

(RXD-) RS-422 Receive Data (Idles low)

2

To AV2 or PRO2

(RXD) RS-232 Received Data

3

From AV2 or PRO2

(TXD) RS-232 Transmitted Data

4

From AV2 or PRO2

(TXD+) RS-422 Transmit Data (Idles high)

5

RS-232 and RS-422 Signal Common

6

To AV2 or PRO2

(RXD+) RS-422 Receive Data (Idles high)

7

From AV2 or PRO2

(RTS) RS-232 Request to Send

8

To AV2 or PRO2

(CTS) RS-232 Clear to Send

9

From AV2 or PRO2

(TXD-) RS-422 Transmit Data (Idles low)

* RS-422 transmit and receive are balanced signals requiring two lines

plus a ground in each direction. RXD+ and TXD+ should idle high (going
low at start of data transmission). RXD- and TXD- should idle low (going
high at start of data transmission). If necessary, RXD+/RXD- and
TXD+/TXD- may be swapped to maintain correct signal levels.

15

INFRARED - SERIAL

OUTPUT (A – H)

9

A B C D

E F G H

S G S G S G S G

INFRARED - SERIAL OUTPUT

S G S G S G S G

(8) 2-pin 3.5 mm detachable terminal blocks IR/Serial output ports.
IR output up to 1.2 MHz; 1-way serial TTL/RS-232 (0-5 Volts) up to
115.2k baud. Individual signal generator per port, allowing
simultaneous firing of all ports.

16

I/O (1 – 8)

10

S6 I/O

1 2 3 4 5 6 7 8 G

(1) 9-pin 3.5 mm detachable terminal block comprising (8) digital
input/output or analog input ports (referenced to GND);
Digital Input: Rated for 0-24 Volts DC, input impedance 20k ohms,
logic threshold 1.24 Volts DC;
Digital Output; 250 mA sync from maximum 24 Volts DC, catch
diodes for use with “real world” loads;
Analog Input: Rated for 0-10 Volts DC, protected to 24 Volts DC
maximum, input impedance 20k ohms;
Programmable 5 Volts, 2k ohms pull-up resistor per pin.

17

RELAY OUTPUT

(1 – 8)

RELAY

S7

1

2

3

4

OUTPUT

5

6

7

8

(2) 8-pin 3.5 mm detachable terminal blocks comprising (8) normally
open, isolated relays;
Rated 1 Amp, 30 Volts AC/DC, MOV arc suppression across
contacts.

18

100 – 240V ~2.4A 50/60 Hz

(POWER SUPPLY)

(1) IEC Socket, mates with removable power cord (included).

19

CHASSIS GROUND

(1) 6-32 screw, chassis ground lug.

1. Interface connectors for NET, Infrared-Serial, I/O and Relay Output ports are provided with the unit.
2. This LED was labeled “ERR” on units manufactured prior to 2005. It is functionally the same; only the labeling has changed.
3. PRO2

only.

4. LAN LEDs are active only if a single port or dual port Ethernet card (which is field installed) occupies the Z-Bus slot.

8

2-Series Integrated Dual Bus Control System: AV2 & PRO2

Operations Guide – DOC. 5957B