Guidelines, Setting client-side optimization – Dell PowerVault DR2000v User Manual
Page 139

Guidelines
For best results, observe the following guidelines for optimal performance with your supported RDA with NVBU and RDA
with vRanger operations with the DR Series system:
•
Back up, restore, and optimized duplication operations performed using the RDA with NVBU or RDA with vRanger
plug-in
NOTE: The plug-in is installed on client systems to support client-side deduplication.
•
Backup:
– Passthrough writes: Passthrough writes are when data is sent from a media server to the DR Series system
without applying any optimization to the data. By contrast, dedupe writes are when data is sent from a media
server to the DR Series system after optimization is applied to the data.
– Dedupe writes
•
Restore
•
Replication
Best Practices: RDA with NVBU and vRanger and the DR Series
System
This topic introduces some recommended best practices for using DR Rapid operations with the DR Series system.
RDS and non-
RDS type
containers can
exist on the same
DR Series system
The DR Series system supports having both RDS and non-RDS containers on the same
appliance. However, this can cause incorrect capacity reporting as both container types share
the same underlying storage.
RDS replication
and non-RDS
replication on the
same DR Series
system
Non-RDS replication must be configured, and it is replicated on a per-container basis.
However, this type of replication will not replicate RDS containers. RDS replication is file-
based and is triggered by the DMA.
Do not change
the container
connection type
from NFS/CIFS to
RDS
A non-RDS container must be deleted before this container can then be created as an RDS
container using the same name.
Setting Client-Side Optimization
Client-side optimization is a process that can contribute to saving time performing backup operations and reducing the
data transfer overhead on the network.
You can turn On or turn Off client-side optimization (also known as client-side deduplication) using the DR Series system
CLI commands, rda --update_client --name --mode. For more information about DR Series system CLI commands, see
the
Dell DR Series System Command Line Reference Guide
, available at support.dell.com/manuals.