Dell 110T DLT1 Drive User Manual
Page 27

Troubleshooting: Dell PowerVault 110T DLT VS160 Tape Drive User's Guide
file:///C|/Users/rishi_sood/Desktop/Temp/MissingDocsPosted/110t_dlt/UG/trouble.htm[3/8/2013 11:46:14 AM]
Illuminated
DLTtape™ IV cartridge is
loaded.
cartridge. If attempting to read, no action is required. Because this cartridge
cannot be written, if you attempt a write operation, your backup application
should return a "Write Protected" message.
Clean LED:
Slow blink
Calibration error or permanent
write/read error.
The drive cannot read the calibration tracks on the tape or has encountered
a permanent write or read error. If the failure is the result of a calibration
error, the drive ejects the cartridge. If the failure is the result of a permanent
read/write error, the drive does not eject the cartridge. Try a known-good
cartridge. If condition persists with a particular cartridge, discard or degauss
that cartridge. If repeatable with a known-good cartridge, try cleaning the
drive. If cleaning does not help, replace the drive or contact Technical
Support.
Clean LED:
Illuminated
Cleaning required.
Drive continues to function, although increased soft error rates may be
encountered. Clean the drive at your earliest convenience. LED indication
remains until drive is cleaned.
Fault LED: Slow
blink
User initiated write/read
diagnostic failed.
Eject tape, power cycle or reset drive. Try diagnostic again with a different,
known-good tape.
NOTICE: This feature overwrites any data currently on the cartridge.
Confirm that the selected cartridge does not contain important data.
If this condition persists with a known-good cartridge, contact Technical
Support.
Fault LED: Fast
blink
Servo or mechanical error.
Power cycle or reset the drive. Try the operation again with a known-good
cartridge. If condition persists, contact Technical Support.
Fault LED:
Illuminated
Internal firmware error.
Power cycle or reset the drive. Try the operation again with a known-good
cartridge. If condition persists, contact Technical Support.
Other LED
Indications
Unspecified.
If you encounter any LED indications that are not covered in this manual,
contact Technical Support. See
Front Panel Controls and Indicators
for a complete LED indicator reference.
helps you troubleshoot other drive and connectivity problems.
Table 2. Drive and connectivity troubleshooting
Symptom
Problem
Solution
The host server
does not
recognize the
drive.
The drive's SCSI ID might not be
unique.
Regardless of the number of SCSI devices attached to the server that
is to be the host for the PowerVault 110T DLT VS160 Tape Internal
drive, each must have a unique SCSI ID. Check the SCSI IDs on all
other SCSI devices on the selected server, including the SCSI host
adapter, and select an unused SCSI ID for the PowerVault 110T DLT
VS160 Tape Internal drive.
NOTE: If you attach the drive to a narrow (50-pin) bus, you can
only use SCSI IDs 0 through 7.
The SCSI host adapter might be
incorrectly configured.
Check the SCSI host adapter configuration. Refer to the SCSI host
adapter manuals for instructions.
The SCSI cable might be loose.
Check both ends of the SCSI cable, both for the external and internal
drives.
The SCSI terminator might be
loose or missing.
1. Make sure an active Low-Voltage Differential/Single-Ended
(LVD/SE) terminator is properly seated on the open SCSI
connector on the rear panel of the external drive or on the last
device on the SCSI bus.